LDC, DC-DC LVDT Displacement Transducer
- LVDT
- Available in Guided, Unguided or Return Spring Version
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable (Longer Cable Available)
- High Accuracy
- High Cycle Life
- Alternative Probe Tips Available (see Related Documents)
- Mounting Blocks Available (see Related Documents)
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensors principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life. Our DC to DC LVDT transducer has all of the benefits of the LVDT sensor principle with the added convenience of built-in LVDT electronics enabling a DC supply and DC output.
This series of displacement transducer is available as either an unguided, captive or spring return version.
Type | LVDT |
Full Scale | 12 mm |
25 mm [0.984"] | |
50 mm | |
75 mm | |
100 mm | |
150 mm | |
200 mm | |
250 mm | |
375 mm | |
470 mm | |
Output | ±2.2 V DC |
Non-Linearity | ±0.10 % FS |
±0.25 % FS | |
±0.50 % FS | |
Resolution | Infinitesimal |
Excitation | 5 - 18 V DC |
Min Temperature | -40 °C |
Max Temperature | 70 °C |
LDC | |
LDC500 | |
LDC1000 | |
LDC2000 | |
LDC3000 | |
LDC4000 | |
LDC6000 | |
LDC8000 | |
LDC10000 | |
LDC15000 | |
LDC18500 |
LDC Series Overview Datasheet |
Probe Tip Alternatives Datasheet |
Mounting Blocks for Large Diameter LVDT Datasheet |
- LVDT
- Analog Output
- Available in Guided, Unguided or Return Spring Versions
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable (Longer Cable Available)
- High Accuracy
- High Cycle Life
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 150 mm, 200 mm, 250 mm, 375 mm, 470 mm |
Output | 4 - 20 mA |
Non-Linearity | ±0.10 % FS, ±0.25 % FS, ±0.50 % FS |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC, 12 - 36 V DC, 24 - 40 V DC |
- LVDT
- Submersible
- Analog Output
- Available in Guided, Unguided or Return Spring Versions
- Rod Profile Housing
- Stainless Steel Housing
- Connection: Many Cable & Connector Options
- High Accuracy
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 100 mm, 150 mm, 200 mm, 250 mm, 375 mm, 470 mm |
Output | 4 - 20 mA |
Non-Linearity | ±0.10 % FS, ±0.25 % FS, ±0.50 % FS |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC, 12 - 36 V DC, 24 - 40 V DC |
- LVDT
- Seawater Submersible
- Available in Unguided Version
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable
- High Accuracy
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 100 mm |
Output | 4 - 20 mA |
Non-Linearity | ±0.50 % FS, ±1.00 % FS |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC, 12 - 36 V DC, 24 - 40 V DC |
- Cylindrical Housing
- Stainless Steel Housing
- Connection: 0.45m Integral Cable
- Free of Hysteresis
- Suitable for Operation in Hydraulic Fluid up to 3 bar
Type | LVDT |
Full Scale | 2.54 mm [0.1"], 5.08 mm, 12.7 mm [0.5"], 25.4 mm [1"], 50.8 mm [2"], 101.6 mm [4"], 152.4 mm [6"] |
Output | V/V DC |
Non-Linearity | ±0.50 % FS, ±1.00 % FS |
Resolution | Infinitesimal |
Excitation | 6 V DC, 15 V DC, 24 V DC, 30 V DC |
- Rod Profile Housing
- Stainless Steel Housing
- Reverse Voltage Protection
- Connection: Models 87350 & 87351: 4.5m Integral Cable
- Connection: Models 87352 - 87356: 5-pin 9947 Plug Connector or 3m Integral Cable
- Free of Hysteresis
- Input & Output Galvanically Separated
Type | LVDT |
Full Scale | 2.54 mm [0.1"], 5.08 mm, 12.7 mm [0.5"], 25.4 mm [1"], 50.8 mm [2"], 101.6 mm [4"], 152.4 mm [6"] |
Output | V/V DC |
Non-Linearity | ±0.50 % FS |
Resolution | Infinitesimal |
Excitation | 6 V DC, 15 V DC, 24 V DC, 28 V DC |