DCTH, DC-DC LVDT Displacement Transducer
- LVDT
- Analog Output
- Available in Guided, Unguided or Return Spring Versions
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable (Longer Cable Available)
- High Accuracy
- High Cycle Life
- Alternative Probe Tips Available (see Related Documents)
- Mounting Blocks Available (see Related Documents)
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life.
Our DC to DC LVDT transducer has all of the benefits of the LVDT sensor principle with the added convenience of built-in LVDT electronics enabling a dc supply and dc output. As an option we can offer a 4-20mA 2 wire connection to the transducer on some models.
Type | LVDT |
Full Scale | 12 mm |
25 mm [0.984"] | |
50 mm | |
75 mm | |
150 mm | |
200 mm | |
250 mm | |
375 mm | |
470 mm | |
Output | 4 - 20 mA |
Non-Linearity | ±0.10 % FS |
±0.25 % FS | |
±0.50 % FS | |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC |
12 - 36 V DC | |
24 - 40 V DC | |
Min Temperature | -10 °C |
-40 °C | |
Max Temperature | 70 °C |
80 °C |
DCTH | |
DCTH100 | |
DCTH200 | |
DCTH300 | |
DCTH400 | |
DCTH500 | |
DCTH1000 | |
DCTH2000 | |
DCTH3000 | |
DCTH4000 | |
DCTH6000 | |
DCTH8000 | |
DCTH10000 | |
DCTH15000 | |
DCTH18500 |
DCTH Series Overview Datasheet |
Probe Tip Alternatives Datasheet |
Large Mounting Block for RDP LVDT Datasheet |
- LVDT
- Submersible
- Analog Output
- Available in Guided, Unguided or Return Spring Versions
- Rod Profile Housing
- Stainless Steel Housing
- Connection: Many Cable & Connector Options
- High Accuracy
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 100 mm, 150 mm, 200 mm, 250 mm, 375 mm, 470 mm |
Output | 4 - 20 mA |
Non-Linearity | ±0.10 % FS, ±0.25 % FS, ±0.50 % FS |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC, 12 - 36 V DC, 24 - 40 V DC |
- LVDT
- Integrated Measuring Amplifier, 0-5 V Output
- Rod Profile Housing
- Nickel-Plated Stainless Steel
- Connection: 2.0 Integral Cable
- Immune to Vibration or Impact
- 0-10 V, 4-20mA Output (Option)
Type | LVDT |
Full Scale | 1 mm, 2 mm, 5 mm, 10 mm, 25 mm [0.984"], 50 mm, 100 mm, 150 mm |
Output | 0 - 5 V DC, 0 - 10 V DC, 4 - 20 mA |
Non-Linearity | ±0.25 % FS |
Resolution | Infinitesimal |
Excitation | 9 - 28 V DC |
- LVDT
- Seawater Submersible
- Available in Unguided Version
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable
- High Accuracy
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 100 mm |
Output | 4 - 20 mA |
Non-Linearity | ±0.50 % FS, ±1.00 % FS |
Resolution | Infinitesimal |
Excitation | 12 - 20 V DC, 12 - 36 V DC, 24 - 40 V DC |
- LVDT
- Integrated Measuring Amplifier, 0-5 V Output
- Rod Profile Housing
- Nickel-Plated Stainless Steel
- Connection: 2.0 Integral Cable
- Immune to Vibration or Impact
- 0-10 V, 4-20mA Output (Option)
Type | LVDT |
Full Scale | 1 mm, 2 mm, 5 mm, 10 mm, 25 mm [0.984"], 50 mm |
Output | 0 - 5 V DC, 0 - 10 V DC, 4 - 20 mA |
Non-Linearity | ±0.15 % FS, ±0.25 % FS |
Resolution | Infinitesimal |
Excitation | 9 - 28 V DC |
- LVDT
- Available in Guided, Unguided or Return Spring Version
- Rod Profile Housing
- Stainless Steel Housing
- Connection: 2m Integral Cable (Longer Cable Available)
- High Accuracy
- High Cycle Life
- Alternative Probe Tips Available (see Related Documents)
Type | LVDT |
Full Scale | 12 mm, 25 mm [0.984"], 50 mm, 75 mm, 100 mm, 150 mm, 200 mm, 250 mm, 375 mm, 470 mm |
Output | ±2.2 V DC |
Non-Linearity | ±0.10 % FS, ±0.25 % FS, ±0.50 % FS |
Resolution | Infinitesimal |
Excitation | 5 - 18 V DC |