4705A, Series Miniature In-Line Charge Amplifiers
- Weight 33 grams
- Size (0.50x3.15 in)
- BNC connectors
Input Type | ±100 pC |
±500 pC | |
±5000 pC | |
±50000 pC | |
# of Inputs | 1 |
Output Type | ±5 V DC |
Max Bandwidth | 2 kHz |
Isolation | No |
Supply Power | 18 - 30 V DC |
4705A2 | Input Range: ±500 pC; Sensitivity: 10 mV/pC |
4705A1 | Input Range: ±100 pC; Sensitivity: 50 mV/pC |
4705A3 | Input Range: ±5000 pC; Sensitivity: 1 mV/pC |
4705A4 | Input Range: ±50000 pC; Sensitivity: 0.1 mV/pC |
4705A Series Miniature In-Line Charge Amplifiers Datasheet |
- Weight 33 grams
- Size (0.50 x 2.56 in)
- 10-32 input connector to BNC output connector
- High frequency response bandwidth depends upon drive current and cable length
- Temperature Range: -46° to +85° C
- Stainless steel
- Epoxy Seal
Input Type | ±100 pC, ±500 pC, ±5000 pC, ±10000 pC |
# of Inputs | 1 |
Output Type | ±5 V DC |
Isolation | No |
Supply Power | 18 - 30 V DC |
- Weight 25 grams
- Size (0.50x1.75 in)
- 10-32 connectors
- Frequency response determined by cable length and output signal scope
- Temperature Range: -46° to +87° C
- Stainless steel
Input Type | ±100 pC, ±500 pC, ±5000 pC, ±50000 pC |
# of Inputs | 1 |
Output Type | ±5 V DC |
Isolation | No |
Supply Power | 18 - 30 V DC |
- 10 mV/pC sensitivity
- Weighs 25 grams
- Fast turn-on time
- Tolerates low insulation resistance from sensors
- 10-32 jack input connector
- High Temperature Sensors
- BNC jack output connector
- Miniature Package
Input Type | ±500 pC, ±1000 pC, ±5000 pC |
# of Inputs | 1 |
Output Type | ±5 V DC |
Max Bandwidth | 40 kHz |
Isolation | No |
Supply Power | 18 - 30 V DC |
- Strain Gauge Input Amplifier
- Accuracy: < 0.10%
- In-Line Amplifier
- Aluminum Housing
- Protection Class: IP40 (IP65 Option)
- Space saving, lightweight
- Non-interchangeable and short circuit-proof
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | ±10 V DC |
Max Bandwidth | 1 kHz |
Excitation | 2.5 V DC |
Isolation | No |
- High Accuracy
- Direct Connection to PLC
- Long Input Lead Possibility from LCV to Evaluation
- Voltage or Current Output
- Integrable in large Sensors as Board
- High Level of Protection IP67
- Tube housing; IP67
- Linearity; 0.02% F.S.
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 1 kHz |
Excitation | 5 V DC |
Isolation | No |