ESP-32HD-DTC, Digitally Temperature Corrected Miniature Pressure Scanner
- Differential or Vented Gauge
- Dry Noncorrosive Gases
- Proof Pressure 4 Times Rated Pressure (≤ 30 psi)
- Proof Pressure 1.5 Times Rated Pressure (> 30 psi)
- 0.040" or 0.063" OD Stainless Steel Tubulation
- Digital Temperature Compensation (Option)
ESP Pressure Scanners are miniature electronic differential pressure measurement units consisting of an array of silicon piezoresistive pressure sensors, one for each pressure port. The sensors are mounted on a common hybrid glass substrate using a proprietary technique which maximizes long term stability. The outputs of the sensors are electronically multiplexed through a single onboard instrumentation amplifier at rates up to 70,000 Hz using binary addressing. The multiplexed amplified analog output is capable of driving long lengths of cable to a remote A/D converter.
The ESP scanners also incorporate a two position calibration manifold actuated by momentary pulses of control pressures. When placed in the calibrate position, all sensors are connected to a common calibration pressure port. A series of accurately measured pressures can be applied through this port to characterize the sensors, in place, at the condition to which they are being subjected. Proper and periodic on-line calibration maintains static errors within +/-0.03% or better of the full scale (FS) pressure range. The calibration manifold automatically switches between two common reference pressures to ensure a stable reference is applied during calibration. The calibration manifold incorporates a visual position indicator and utilizes a dynamic o-ring seal design for high reliability and easy servicing in the field.
Options include purge capability, isolated from the pressure sensors, to clear measurement lines of moisture and contamination as well as to prevent closure of model pressure taps during application of pressure sensitive paint. Other options include a nickel foil RTD output to monitor internal scanner temperature and Digital Temperature Compensation technology now incorporating PSI’s Gen-2 amplifier technology.
The Digital Temperature Compensation (DTC) option incorporates the latest PSI innovations in ESP technology including temperature signal outputs from each silicon pressure sensor, embedded EEPROM retaining factory calibration information including temperature characteristics, programmable dual gain amplifier with optional dual range calibration, calibration manifold position sensing, and internal sensor excitation regulation with sense output. DTC Series ESP scanners are supported by PSI’s DTC Initium System and the SDI configuration of the System 8400 to dramatically reduce calibration requirements. The ESP scanners are also supported by a variety of third party compatible systems.
Type | Scanner |
# of Channels | 32 |
Operational Mode | Differential |
Full Scale | 1 psi |
2.5 psi | |
5 psi | |
10 psi | |
15 psi | |
30 psi | |
45 psi | |
50 psi | |
100 psi | |
Output | ESP |
ESP-DTC | |
Precision | ±0.03 % FS |
±0.06 % FS | |
±0.15 % FS | |
Excitation | 5 V DC |
12 V DC | |
Technology | Silicon Piezoresistive |
Min Temperature | -25 °C |
Max Temperature | 80 °C |
32HD | 32-Channel Pressure Scanner |
32HC-0200000000 | ESP-32HD-DTC Heater Chamber |
Specifications for 32HD-DTC & 64HD-DTC Miniature Scanners
Note - the performance stated is after 1 hour of power to the scanner and Reference Port at atmosphere pressure. The Heater Chambers for the DTC Scanners are only needed to maintain the temperature within the Operating Temperature Range.
Notes for the above Table
Ordering Information
ESP-32HD Miniature Pressure Scanner Datasheet |
- Differential or Vented Gauge
- Dry Noncorrosive Gases
- Proof Pressure 4 Times Rated Pressure (≤ 30 psi)
- Proof Pressure 1.5 Times Rated Pressure (> 30 psi)
- 0.040" or 0.063" OD Stainless Steel Tubulation
- Digital Temperature Compensation (Option)
Type | Scanner |
# of Channels | 64 |
Operational Mode | Differential |
Full Scale | 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 50 psi, 100 psi |
Output | ESP, ESP-DTC |
Precision | ±0.03 % FS, ±0.06 % FS, ±0.15 % FS |
- Support for 8 DTC Series ESP Scanners, 32 or 64 port Scanners
- For up to 512 Pressure Channels
- ±0.05% FS Precision after Rezero
- 1000 Hz per Channel Throughput in Engineering Units for 128 ports
- Syncronized Data with Accelerometers, Wet Pressures, etc.
- Auto-negotiating 10/100 Base-T Ethernet Interface
- Compact Robust Package, with an optional Protective Enclosure
- Comprehensive Applications Utility Software
Type | Scanner |
Interface | ESP-DTC |
# of Scanners | 8 |
Output | Ethernet |
Excitation | 18 - 36 V DC |
Min Temperature | 0 °C |
- Wind-tunnel Pressure Scanning System
- ESP Pressure Scanner Compatible
- Up to +/- 0.03% Accuracy
- Up to 2000 Hz/port EU Data Throughput
- DTC Digital Temperature Compensation Technology
- Miniature Scanner Digitizing Interface
- On Line Calibration
- On Line Verification
Type | Scanner |
Interface | ESP, ESP-DTC |
# of Scanners | 8 |
Output | Ethernet |
Min Temperature | -25 °C |
Max Temperature | 100 °C |
- Multi-channel - 16, 32 or 64 pressure ports
- Intelligent • pressure scanner module with engineering unit output
- Compatible with all PSI Pressure Scanners
- Up to 0.05% FS accuracy output
- Up to 2Khz per channel measurement frequency
- Output over Ethernet (100Mbit TCP / UDP) and CAN
- Rugged enclosure for on-vehicle applications
- Supplied with full software for configuration, calibration and data logging
- 19, 37, 55 & 73 Ports for Circular units
- Stainless Steel bulged tubes for 0.040" or 0.063" ID pressure tubing
- Available with mating halves of 0.040" & 0.063" Tubing Sizes
- Can handle pressures up to 750 psi.
- Bulk Head & In-Line models are available
- Blank Halves are available for Dead-ending the Pneumatic Lines
- tubing, nylon & polyurethane, retaining springs & tubing pliers are available
- Easy connections that can handle pressures up to 750 psi.
- Compliments our miniature ESP Pressure Scanners
- Individual Port with Static O-ring Configuration
- Available with 0.040", 0.063" nominal inner diameter pressure tubing
- 19, 31, 36 and 55 port versions
- tubes are in a Pyramid shape for ease of connection
- Stainless hex nut with locator pins
- Silicon Gasket
- Differential or Vented Gauge
- Dry Noncorrosive Gases
- Proof Pressure 4 Times Rated Pressure (≤ 30 psi)
- Proof Pressure 1.5 Times Rated Pressure (> 30 psi)
- 0.040" or 0.063" OD Stainless Steel Tubulation
- Digital Temperature Compensation (Option)
Type | Scanner |
# of Channels | 64 |
Operational Mode | Differential |
Full Scale | 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 50 psi, 100 psi |
Output | ESP, ESP-DTC |
Precision | ±0.03 % FS, ±0.06 % FS, ±0.15 % FS |
- This product has been discontinued & replaced with the 32HD-DTC
- Differential or Vented Gauge
- Dry Noncorrosive Gases
- Proof Pressure 4 Times Rated Pressure (¡Ü 30 psi)
- Proof Pressure 1.5 Times Rated Pressure (> 30 psi)
- 0.040" or 0.063" OD Stainless Steel Tubulation
Type | Scanner |
# of Channels | 16 |
Operational Mode | Differential |
Full Scale | 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 50 psi, 100 psi |
Output | ESP, ESP-DTC |
Precision | ±0.03 % FS, ±0.06 % FS, ±0.15 % FS |
- 16 and 32 channel Intelligent pressure scanner module with engineering unit output.
- User selectable absolute or differential measurement
- Up to 0.03% FS accuracy output.
- Complete with IEEE 1588 PTPv2 time stamping
- Thermally compensated from -20 to 100ºC
- Output over Ethernet (100Mbit TCP / UDP) and CAN.
- Rugged enclosure for on-vehicle applications.
- Sealed to IP67
Type | Scanner |
# of Channels | 16, 32 |
Operational Mode | Absolute, Differential |
Full Scale | 2 psi, 23 psi |
Output | Ethernet, CANOpen |
Precision | ±0.03 % FS |
- Differential or Absolute compensated engineering unit pressure data
- Precision measurements are provided by dual 24-bit ADC’s for pressure & temperature
- Electrically Driven Valve (optional) gives the scanner a purge and re-zero facility.
- Precise Temperature measurement compensates for thermal effects on the Pressure Measurements.
- Pressure Ranges from 4”WC up to 45 psid and 16 to 58 psia
Type | Scanner |
# of Channels | 64 |
Operational Mode | Absolute, Differential |
Full Scale | 0.5 psi, 50 psi |
Output | Ethernet, CANOpen |
Precision | ±0.03 % FS, ±0.06 % FS |