Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

T400, Speed - Frequency Signal Conditioner & Transmitter - DISCONTINUED

Converts absolute speed into a continuous analogue signal using the precise and rapid conversion technique of period of time elapsed between pulse inputs.
T401-T411
T401-T411
T401-T402_conversion
T411-T412_conversion
Features:
  • T401 / T402 provide an analog output of 4(0)-20ma or 2(0)-10 Vdc
  • T411 and T412 models are panel Mount display versions
  • Isolated input with automatic trigger level adjustment
  • 2 limit set points with programmable hysteresis
  • Windows Explorer configuration software allows:
  • • Quick and easy configuration of all operating parameters
  • • Unit interrogation of identity and parameters
  • • PC display of current measurement and relay status
  • • Archiving and printing of the configuration
Manufacturer:  Jaquet North America Inc.
Quote
Datasheet
Description
Specifications
Applications
Models & Accessories
Downloads
Related Products
Similar Products
T400 - Description

The analogue signal (Vdc or ma) is achieved using the measurement of the time that elapses (Period Measurement) between any 2 consecutive input pulses, referencing a precision clock and using only a few pulses. The Period Measurement conversion is far superior to the method of counting pulses, as it reacts to the rate of the pulses, that in turn relates to the speed of rotation.

T402 / T412 alternative uses the T401 / T411 to create the 0(2)..10 V output. This is achieved by using a T401 / T411 with a 500 Ω / 0.1% / ¼ W resistor across the (0)4-20 mA output terminals.

                

                    T401 conversion to T402                                                                   T411 conversion to T412

T400 - Specifications
InterfaceRS-232
Input TypeFrequency
# of Inputs1
Output Type0 - 10 V DC
2 - 10 V DC
0 - 20 mA
4 - 20 mA
IsolationYes
Supply Power10 - 36 V DC
IP RatingIP 40
T400 - Applications

- Diesel engine start control and over speed protection
- Micro Turbine measurement and protection
- Turbocharger speed measurement
- Machine protection in safety critical applications
- Universal speed measurement and indication
- Usable as SIL2 safety relay together with JAQUET’s IQ-Sensor (see T420 application note)

T400 - Models & Accessories
Models
T400
T401Current Output, without Display
T402Voltage Output, without Display
T411Current Output, with Display
T412Voltage Output, with Display
T400 - Downloads
T400 - Related Products
  • Accepts 1 signal input from 3-wire voltage sensors (Hall-effect & proximity),
  • Accepts 2-wire voltage signals or digital input signals from encoders.
  • Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
  • Input Voltage Ranges from 20 mVrms to 80 Vrms
  • Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
  • Two configurable relays (10 ms response time) for multiple speed functions
  • One highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
  • One Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface
TCP/IP,
RS-485
Input Type
20 milli Vrms,
0 - 10 V AC,
80 Vrms,
Frequency
# of Inputs
1
Output Type
2 - 10 V DC,
4 - 20 mA
Max Bandwidth
10 kHz
Excitation
24 V DC
T400 - Similar Products
  • Programmable Isolated Transmitters
  • Universal Counter
  • Teach- In, Digital Filter, Tare
  • Output: 0/4...20 mA/0...5 mA/0...2/5/10 V/10V
  • Power Supply 10...30 V AC/DC
  • Option: Comparators, Data Output
  • Isolated
  • Accuracy: ±0,05 % of value UQC
Interface
USB
Input Type
Frequency,
Counter
# of Inputs
1
Output Type
0 - 2 V DC,
0 - 5 V DC,
0 - 10 V DC,
±10 V DC,
0 - 5 mA,
0 - 20 mA,
4 - 20 mA,
RS-485
Isolation
Yes
Supply Power
10 - 30 V DC,
10 - 30 V AC
  • Selectable frequency ranges up to 32 kHz
  • Selectable input threshold levels
  • Capacitive coupling for magnetic pickup inputs
  • Selectable filtering on the amplified signal output
  • Effective signal isolation & ESD protection
Input Type
Frequency
# of Inputs
1
Output Type
0 - 5 V DC,
0 - 10 V DC,
4 - 20 mA
Max Bandwidth
125 Hz
Excitation
10 V DC
Isolation
Yes
  • For Frequency Signals
  • 1500 V AC I/O Isolation
  • Accuracy: 0.02% F.S.
  • DIN-Rail, Panel or Fixture Mount
  • Overvoltage Protection
  • Extruded Aluminum Casing
Interface
RS-232
Input Type
Frequency
# of Inputs
1
Output Type
0 - 5 V DC,
0 - 10 V DC
Max Bandwidth
2 kHz
Excitation
10 V DC
  • Strain Gauge & Potentiometer Input Amplifier
  • 50 V Continuous Isolation
  • Accuracy: ± 0.05%
  • DIN Rail Mounted
  • In-Line Amplifier (Option)
  • Aluminum Housing
  • Protection Class: IP40
Input Type
0 - 10 mV DC,
0 - 100 mV DC,
0 - 1 V DC,
0 - 10 V DC,
±10 V DC,
Potentiometer,
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
1 kHz,
4 kHz
Excitation
2.5 V DC,
5 V DC,
10 V DC
Isolation
Yes
  • Frequency Input Module
  • 1500 V Transformer Isolation
  • True 3-Way Isolation
  • Accuracy: ± 0.03%
  • DIN Rail Mounted Module
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240 V AC Continuous
Input Type
Frequency
# of Inputs
1
Output Type
0 - 10 V DC,
0 - 20 mA,
4 - 20 mA
Excitation
5 V DC
Isolation
Yes
Supply Power
19 - 29 V DC
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us