8106, Flush Diaphragm Pressure Transducer/Transmitter (Discontinued)
- Discontinued
- Non-Magnetic
- Titanium, Corrosion-Resistant
- Resonance Frequency 28 kHz - 229 kHz (73 psi - 14500 psi)
- Over Pressure 3 Times Rated Pressure
- Protection Class IP65
- Superb Long-Term Stability
These pressure transducers are made entirely of titanium.
The diaphragm used as the sensor element is fashioned
from the solid material, and strain gauges are applied to its
inner face. These convert the displacement of the diaphragm
into a change in electrical resistance, which can be amplified,
measured and processed by built-in or external electronic
circuitry.
The transducers come in a choice of measuring ranges: the
gauge sensor (measurements with respect to atmospheric
pressure) is available in ranges up to 0 ... 20 bar, and the
sealed sensor (measurements with respect to a sealed atmosphere)
for the 0 ... 50 bar range upwards.
Their outstanding properties include excellent resistance to
corrosion, extremely small hysteresis and superb long-term
stability plus value for money and high dynamic load performance
of up to 108
load changes.
Type | Industrial |
Flush Diaphragm | |
Operational Mode | Sealed Gauge |
Full Scale | 29 psi |
73 psi | |
145 psi | |
290 psi | |
725 psi | |
1450 psi | |
2900 psi | |
7250 psi | |
14500 psi | |
Output | 4 - 20 mA |
Precision | ±0.50 % FS |
Excitation | 14 - 30 V DC |
Technology | Strain Gauge |
Material | Titanium |
Thread | Unthreaded |
Min Temperature | -25 °C |
Max Temperature | 85 °C |
These transducers can be used anywhere thanks to their
small size. The construction principle of a flush front diaphragm
means they are particularly suitable for applications
in which a dead volume is unacceptable, or only a very small
dead volume can be tolerated.
Another suitable use is in environments where the nature of
the medium makes a measurement chamber unsuitable e.g.
in the food industry or chemical engineering. With a choice
of threaded and welded adapters available, the range of applications
can be widened still further.
8106 Pressure Transducer/Transmitter Datasheet |
8106-5 CAD Drawing Drawings |
8106-10 CAD Drawing Drawings |
8106-20 CAD Drawing Drawings |
8106-50 CAD Drawing Drawings |
8106-100 CAD Drawing Drawings |
8106-200 CAD Drawing Drawings |
8106-500 CAD Drawing Drawings |
8106-1000 CAD Drawing Drawings |
- Discontinued
- Non-Magnetic
- Titanium, Corrosion-Resistant
- Resonance Frequency 28 kHz - 229 kHz (73 psi - 14500 psi)
- Over Pressure 3 Times Rated Pressure
- Protection Class IP65
- Superb Long-Term Stability
Type | Industrial, Flush Diaphragm |
Operational Mode | Sealed Gauge, Vented Gauge |
Full Scale | 29 psi, 73 psi, 145 psi, 290 psi, 725 psi, 1450 psi, 2900 psi, 7250 psi, 14500 psi |
Output | 4 - 20 mA |
Precision | ±0.50 % FS |
Excitation | 14 - 30 V DC |