OMX 39OHM, DIN Resistance Signal Conditioner
- Transmitter for Ohmmeter
- Transmitters have galvanic separation with isolation voltage of 600 V
- By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of ±10%
- Accuracy: ±0,2 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | Resistance |
# of Inputs | 1 |
Output Type | 0 - 2 V DC |
0 - 5 V DC | |
0 - 10 V DC | |
±10 V DC | |
0 - 20 mA | |
4 - 20 mA | |
±20 mA | |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC |
10 - 30 V AC | |
80 - 250 V AC | |
IP Rating | IP 20 |
OMX39OHM Datasheet |
- DC Voltmeter and Ammeter
- Transmitters have galvanic separation with isolation voltage of 600 V
- By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of ±10%
- Accuracy: ±0,1 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | 0 - 450 V DC, 0 - 5 A |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |
- Process Monitor
- Transmitters have galvanic separation with isolation voltage of 600 V
- By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of ±10%
- Accuracy: ±0,1 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, 0 - 5 mA, 0 - 20 mA, 4 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |
- AC Voltmeter and Ammeter
- Transmitters have galvanic separation with isolation voltage of 600 V
- Accuracy: ±0.3 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | 0 - 450 V AC, 0 - 5 A AC |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |
- Transmitter for Wattmeter
- Transmitters have galvanic separation with isolation voltage of 600 V
- By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of ±10%
- Accuracy: ±0,5 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | Power |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |
- Transmitter for Thermometer - PT/NI
- Transmitters have galvanic separation with isolation voltage of 600 V
- By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of ±10%
- Accuracy: ±0,2 % of range RTD
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |