SCM7B35, Transmitter Interface Process Control Signal Conditioner
- 2-Wire Transmitter Interface Module with Loop Power
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | 4 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
1 - 5 V DC | |
0 - 10 V DC | |
2 - 10 V DC | |
Bandwidth | 100 Hz |
Isolation | Yes |
Supply Power | 18 - 30 V DC |
SCM7B35-01 | 4-20 mA Input, 1-5 V Output |
SCM7B35-01A | 4-20 mA Input, 0-5 V Output |
SCM7B35-01D | 4-20 mA Input, 0-10 V Output |
SCM7B35-02 | 4-20 mA Input, 2-10 V Output |
SCM7B35 Datasheet |
AN101 RMS_Voltage_Current App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN704-SCM7B Failure Rate and Calc. Prediction App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Sample Test Report Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Current Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | 0 - 20 mA, 4 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 100 Hz |
Isolation | Yes |
- Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | 0 - 5 V DC, 1 - 5 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 100 Hz |
Isolation | Yes |
- Current Output Module
- 1500 Vrms Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- ANSI/IEEE C37.90.1 Transient Protection
- Output Protected to 120 V AC Continuous
- CSA C/US Certified
- CE and ATEX Compliant
Family | Dataforth 7B |
Input Type | 1 - 5 V DC, 0 - 10 V DC, 4 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 20 mA, 4 - 20 mA |
Bandwidth | 100 Hz |
Isolation | Yes |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.06% to ± 0.07%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
Family | Dataforth 5B, Dataforth 7B |
Input Type | 0 - 10 mV DC, 0 - 40 V DC, ±10 V DC, 0 - 10 V AC, 4 - 20 mA, Strain Gauge, Frequency |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
Isolation | Yes |