SCM7B47, Thermocouple Input Process Control Signal Conditioner
- Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.06%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
- Simple DIN Rail Mounting
Family | Dataforth 7B |
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
1 - 5 V DC | |
0 - 10 V DC | |
Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 14 - 35 V DC |
SCM7B47J-01 | J-Type Thermocouple, 0 to 760°C Input, 1-5 V DC Output |
SCM7B47J-02 | J-Type Thermocouple, -100 to 300°C Input, 1-5 V DC Output |
SCM7B47K-03 | K-Type Thermocouple, 0 to 1300°C Input, 1-5 V DC Output |
SCM7B47K-04 | K-Type Thermocouple, 0 to 600°C Input, 1-5 V DC Output |
SCM7B47T-05 | T-Type Thermocouple, 0 to 400°C Input, 1-5 V DC Output |
SCM7B47T-06 | T-Type Thermocouple, -100 to 200°C Input, 1-5 V DC Output |
SCM7B47E-07 | E-Type Thermocouple, 0 to 900°C Input, 1-5 V DC Output |
SCM7B47R-08 | R-Type Thermocouple, 500 to 1750°C Input, 1-5 V DC Output |
SCM7B47S-09 | S-Type Thermocouple, 700 to 1750°C Input, 1-5 V DC Output |
SCM7B47B-10 | B-Type Thermocouple, 800 to 1800°C Input, 1-5 V DC Output |
SCM7B47N-11 | N-Type Thermocouple, 200 to 1300°C Input, 1-5 V DC Output |
SCM7B47J-01A | J-Type Thermocouple, 0 to 760°C Input, 0-5 V DC Output |
SCM7B47J-02A | J-Type Thermocouple, -100 to 300°C Input, 0-5 V DC Output |
SCM7B47K-03A | K-Type Thermocouple, 0 to 1300°C Input, 0-5 V DC Output |
SCM7B47K-04A | K-Type Thermocouple, 0 to 600°C Input, 0-5 V DC Output |
SCM7B47T-05A | T-Type Thermocouple, 0 to 400°C Input, 0-5 V DC Output |
SCM7B47T-06A | T-Type Thermocouple, -100 to 200°C Input, 0-5 V DC Output |
SCM7B47E-07A | E-Type Thermocouple, 0 to 900°C Input, 0-5 V DC Output |
SCM7B47R-08A | R-Type Thermocouple, 500 to 1750°C Input, 0-5 V DC Output |
SCM7B47S-09A | S-Type Thermocouple, 700 to 1750°C Input, 0-5 V DC Output |
SCM7B47B-10A | B-Type Thermocouple, 800 to 1800°C Input, 0-5 V DC Output |
SCM7B47N-11A | N-Type Thermocouple, 200 to 1300°C Input, 0-5 V DC Output |
SCM7B47J-01D | J-Type Thermocouple, 0 to 760°C Input, 0-10 V DC Output |
SCM7B47J-02D | J-Type Thermocouple, -100 to 300°C Input, 0-10 V DC Output |
SCM7B47K-03D | K-Type Thermocouple, 0 to 1300°C Input, 0-10 V DC Output |
SCM7B47K-04D | K-Type Thermocouple, 0 to 600°C Input, 0-10 V DC Output |
SCM7B47T-05D | T-Type Thermocouple, 0 to 400°C Input, 0-10 V DC Output |
SCM7B47T-06D | T-Type Thermocouple, -100 to 200°C Input, 0-10 V DC Output |
SCM7B47E-07D | E-Type Thermocouple, 0 to 900°C Input, 0-10 V DC Output |
SCM7B47R-08D | R-Type Thermocouple, 500 to 1750°C Input, 0-10 V DC Output |
SCM7B47S-09D | S-Type Thermocouple, 700 to 1750°C Input, 0-10 V DC Output |
SCM7B47B-10D | B-Type Thermocouple, 800 to 1800°C Input, 0-10 V DC Output |
SCM7B47N-11D | N-Type Thermocouple, 200 to 1300°C Input, 0-10 V DC Output |
SCM7B47 Datasheet |
AN101 RMS_Voltage_Current App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN704-SCM7B Failure Rate and Calc. Prediction App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Sample Test Report Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05% to ± 0.15%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.06% to ± 0.07%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Non-Linearized Isolated Thermocouple Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Analog Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | 0 - 10 mV DC, 0 - 100 mV DC, 0 - 1 V DC, 1 - 5 V DC, ±10 mV DC, ±100 mV DC, ±1 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Analog Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounting with DIN Backpanel
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 120 V AC Continuous
Family | Dataforth 7B |
Input Type | 0 - 5 V DC, 0 - 10 V DC, 0 - 20 V DC, 0 - 50 V DC, ±5 V DC, ±10 V DC, ±20 V DC, ±50 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 1 - 5 V DC, 0 - 10 V DC |
Bandwidth | 3 Hz |