8B33, RMS Input Analog Signal Conditioner Modules
- True RMS Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.25%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 350 V AC Continuous
Family | Dataforth 8B |
Input Type | 0 - 100 mV AC |
0 - 1 V AC | |
0 - 10 V AC | |
0 - 150 V AC | |
0 - 300 V AC | |
0 - 1 A AC | |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Isolation | Yes |
Supply Power | 5 V DC |
8B33-01 | 0-100 mV Input, 0-5 V DC Output |
8B33-02 | 0-1 V Input, 0-5 V DC Output |
8B33-03 | 0-10 V Input, 0-5 V DC Output |
8B33-04 | 0-150 V Input, 0-5 V DC Output |
8B33-05 | 0-300 V Input, 0-5 V DC Output |
8B33-06 | 0-1 A Input, 0-5 V DC Output |
8B33 Datasheet |
8B Accessories Datasheet |
8B Signal Conditioners Overview Datasheet |
8B Module Diagram Drawings |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN127 OP-Amp Errors, another View App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioner Life Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | ±1 V DC, ±5 V DC, ±10 V DC, ±20 V DC, ±40 V DC, ±60 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, ±5 V DC |
Bandwidth | 1 kHz |
Isolation | Yes |
- Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | ±1 V DC, ±5 V DC, ±10 V DC, ±20 V DC, ±40 V DC, ±60 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, ±5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Current Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | 0 - 20 mA, 4 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.10°C to ± 0.45°C
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 350 V AC Continuous
Family | Dataforth 8B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Linearized 4-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.10°C to ± 0.45°C
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |