8B37, Thermocouple Input Analog Signal Conditioner Modules
- Non-Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 5 V DC |
8B37J | J-Type Thermocouple, -100 to 760°C Input, 0-5 V DC Output |
8B37K | K-Type Thermocouple, -100 to 1350°C Input, 0-5 V DC Output |
8B37T | T-Type Thermocouple, -100 to 400°C Input, 0-5 V DC Output |
8B37R | R-Type Thermocouple, 0 to 1750°C Input, 0-5 V DC Output |
8B37S | S-Type Thermocouple, 0 to 1750°C Input, 0-5 V DC Output |
8B37 Datasheet |
8B Accessories Datasheet |
8B Signal Conditioners Overview Datasheet |
8B Module Diagram Drawings |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN127 OP-Amp Errors, another View App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Linearized Thermocouple Input Module
- 1500 V Isolation
- Accuracy: ± 0.10% to ± 0.20%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Linearized 4-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.10°C to ± 0.45°C
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.10°C to ± 0.45°C
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 350 V AC Continuous
Family | Dataforth 8B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Accepts Millivolt and Voltage Level Signals
- High-Level Voltage Outputs
- Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | ±10 mV DC, ±50 mV DC, ±100 mV DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, ±5 V DC |
Bandwidth | 3 Hz |
Isolation | Yes |
- Strain Gauge Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.05%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 8B |
Input Type | ±10 mV DC, ±20 mV DC, ±30 mV DC, Strain Gauge |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, ±5 V DC |
Bandwidth | 3 Hz, 8 kHz |
Excitation | 3.33 V DC, 10 V DC |