DSCA36, Potentiometer Input Analog Signal Conditioner DIN Rail Modules
- Potentiometer Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Potentiometer |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
0 - 20 mA | |
4 - 20 mA | |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
DSCA36-01 | 0 to 100 Ω Input, 0-10 V Output |
DSCA36-02 | 0 to 500 Ω Input, 0-10 V Output |
DSCA36-03 | 0 to 1 kΩ Input, 0-10 V Output |
DSCA36-04 | 0 to 10 kΩ Input, 0-10 V Output |
DSCA36-01C | 0 to 100 Ω Input, 4-20 mA Output |
DSCA36-02C | 0 to 500 Ω Input, 4-20 mA Output |
DSCA36-03C | 0 to 1 kΩ Input, 4-20 mA Output |
DSCA36-04C | 0 to 10 kΩ Input, 4-20 mA Output |
DSCA36-01E | 0 to 100 Ω Input, 0-20 mA Output |
DSCA36-02E | 0 to 500 Ω Input, 0-20 mA Output |
DSCA36-03E | 0 to 1 kΩ Input, 0-20 mA Output |
DSCA36-04E | 0 to 10 kΩ Input, 0-20 mA Output |
DSCA36 V2 Datasheet |
DSCA36 Datasheet |
DSCA Series Datasheet |
DSCA Dimensions Drawings |
DSCA Calibration Procedure App Note |
Sample Test Report Tech Note |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN801 DSCA Calibration Procedure App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Why Isolation (White Paper) Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Interfaces to Potentiometers up to 10 kOhm
- Process Current Output
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input and Output Protected to 240VAC Continuous
- Up to 60V Loop Voltage
- 160dB CMR
- 85dB NMR at 60Hz, 80dB at 50Hz
Input Type | Potentiometer |
# of Inputs | 1 |
Output Type | 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 12 - 60 V DC |
- Strain Gauge & Potentiometer Input Amplifier
- 50 V Continuous Isolation
- Accuracy: ± 0.05%
- DIN Rail Mounted
- In-Line Amplifier (Option)
- Aluminum Housing
- Protection Class: IP40
Input Type | 0 - 10 mV DC, 0 - 100 mV DC, 0 - 1 V DC, 0 - 10 V DC, ±10 V DC, Potentiometer, Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 1 kHz, 4 kHz |
Excitation | 2.5 V DC, 5 V DC, 10 V DC |
Isolation | Yes |
- Voltage Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | 0 - 10 mV DC, 0 - 50 mV DC, 0 - 100 mV DC, ±10 mV DC, ±50 mV DC, ±100 mV DC |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
- Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.08%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
- Non-Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.05%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |