DSCA47, Thermocouple Input Analog Signal Conditioner DIN Rail Modules
- Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.08%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
0 - 20 mA | |
4 - 20 mA | |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
DSCA47J-01 | J-Type Thermocouple, 0 to 760°C Input, 0-10 V DC Output |
DSCA47J-02 | J-Type Thermocouple, -100 to 300°C Input, 0-10 V DC Output |
DSCA47J-03 | J-Type Thermocouple, 0 to 500°C Input, 0-10 V DC Output |
DSCA47K-04 | K-Type Thermocouple, 0 to 1000°C Input, 0-10 V DC Output |
DSCA47K-05 | K-Type Thermocouple, 0 to 500°C Input, 0-10 V DC Output |
DSCA47K-13 | K-Type Thermocouple, -100 to 1350°C Input, 0-10 V DC Output |
DSCA47K-14 | K-Type Thermocouple, 0 to 1200°C Input, 0-10 V DC Output |
DSCA47T-06 | T-Type Thermocouple, -100 to 400°C Input, 0-10 V DC Output |
DSCA47T-07 | T-Type Thermocouple, 0 to 200°C Input, 0-10 V DC Output |
DSCA47E-08 | E-Type Thermocouple, 0 to 1000°C Input, 0-10 V DC Output |
DSCA47R-09 | R-Type Thermocouple, 500 to 1750°C Input, 0-10 V DC Output |
DSCA47S-10 | S-Type Thermocouple, 500 to 1750°C Input, 0-10 V DC Output |
DSCA47B-11 | B-Type Thermocouple, 500 to 1800°C Input, 0-10 V DC Output |
DSCA47N-15 | N-Type Thermocouple, -100 to 1300°C Input, 0-10 V DC Output |
DSCA47J-01C | J-Type Thermocouple, 0 to 760°C Input, 4-20 mA Output |
DSCA47J-02C | J-Type Thermocouple, -100 to 300°C Input, 4-20 mA Output |
DSCA47J-03C | J-Type Thermocouple, 0 to 500°C Input, 4-20 mA Output |
DSCA47K-04C | K-Type Thermocouple, 0 to 1000°C Input, 4-20 mA Output |
DSCA47K-05C | K-Type Thermocouple, 0 to 500°C Input, 4-20 mA Output |
DSCA47K-13C | K-Type Thermocouple, -100 to 1350°C Input, 4-20 mA Output |
DSCA47K-14C | K-Type Thermocouple, 0 to 1200°C Input, 4-20 mA Output |
DSCA47T-06C | T-Type Thermocouple, -100 to 400°C Input, 4-20 mA Output |
DSCA47T-07C | T-Type Thermocouple, 0 to 200°C Input, 4-20 mA Output |
DSCA47E-08C | E-Type Thermocouple, 0 to 1000°C Input, 4-20 mA Output |
DSCA47R-09C | R-Type Thermocouple, 500 to 1750°C Input, 4-20 mA Output |
DSCA47S-10C | S-Type Thermocouple, 500 to 1750°C Input, 4-20 mA Output |
DSCA47B-11C | B-Type Thermocouple, 500 to 1800°C Input, 4-20 mA Output |
DSCA47N-15C | N-Type Thermocouple, -100 to 1300°C Input, 4-20 mA Output |
DSCA47J-01E | J-Type Thermocouple, 0 to 760°C Input, 0-20 mA Output |
DSCA47J-02E | J-Type Thermocouple, -100 to 300°C Input, 0-20 mA Output |
DSCA47J-03E | J-Type Thermocouple, 0 to 500°C Input, 0-20 mA Output |
DSCA47K-04E | K-Type Thermocouple, 0 to 1000°C Input, 0-20 mA Output |
DSCA47K-05E | K-Type Thermocouple, 0 to 500°C Input, 0-20 mA Output |
DSCA47K-13E | K-Type Thermocouple, -100 to 1350°C Input, 0-20 mA Output |
DSCA47K-14E | K-Type Thermocouple, 0 to 1200°C Input, 0-20 mA Output |
DSCA47T-06E | T-Type Thermocouple, -100 to 400°C Input, 0-20 mA Output |
DSCA47T-07E | T-Type Thermocouple, 0 to 200°C Input, 0-20 mA Output |
DSCA47E-08E | E-Type Thermocouple, 0 to 1000°C Input, 0-20 mA Output |
DSCA47R-09E | R-Type Thermocouple, 500 to 1750°C Input, 0-20 mA Output |
DSCA47S-10E | S-Type Thermocouple, 500 to 1750°C Input, 0-20 mA Output |
DSCA47B-11E | B-Type Thermocouple, 500 to 1800°C Input, 0-20 mA Output |
DSCA47N-15E | N-Type Thermocouple, -100 to 1300°C Input, 0-20 mA Output |
DSCA47 V2 Datasheet |
DSCA47 Datasheet |
DSCA Series Datasheet |
DSCA Dimensions Drawings |
DSCA Calibration Procedure App Note |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN127 OP-Amp Errors, another View App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN801 DSCA Calibration Procedure App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Sample Test Report Tech Note |
Why Isolation (White Paper) Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Non-Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.05%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.08%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 15 - 30 V DC |
- Interfaces to 100 Ohm Platinum or 120 Ohm Nickel RTDs
- Linearizes RTD Signal
- Process Current Output
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input and Output Protected to 240VAC Continuous
- Up to 60V Loop Voltage
- 160dB CMR
Input Type | RTD |
# of Inputs | 1 |
Output Type | 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 12 - 60 V DC |
- Interfaces to Types J, K, T, E, R, S, B, and N Thermocouples
- Process Current Output
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input and Output Protected to 240VAC Continuous
- Up to 60V Loop Voltage
- 160dB CMR
- 85dB NMR at 60Hz, 80dB at 50Hz
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 12 - 60 V DC |
- Interfaces to Types J, K, T, E, R, S, B, and N Thermocouples
- Linearizes Thermocouple Signal
- Process Current Output
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input and Output Protected to 240VAC Continuous
- Up to 60V Loop Voltage
- 160dB CMR
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 4 - 20 mA |
Max Bandwidth | 3 Hz |
Isolation | Yes |
Supply Power | 12 - 60 V DC |