CRFX/BR2-4, imc CRONOSflex Module
- imc CRONOSflex Bridge Measurement Amplifier
- 4 Analog Input Channels
- Carrier Frequency Excitation (5 kHz) for Bridges & LVDT
- Supports Single & Dual Sense Line Configurations
- Symmetric Bridge Supply of 1 V, 2.5 V, 5 V with DC & AC Mode
- Broken Wire Detection
- Integrated Calibration Resistor for Shunt Calibration
- Software Selectable Quarter-Bridge Completion 120 & 350 ohms
- Graphical Configuration Wizard to Set Strain Gauge Bridges
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage |
Current | |
Strain Gauge | |
ICP | |
Analog Inputs | 4 |
Max Bandwidth | 14 kHz |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
24-bit | |
Min Temperature | -10 °C |
-40 °C | |
Max Temperature | 55 °C |
85 °C | |
IP Rating | IP20 |
CRFX/BR2-4 | 4 Analog Inputs, DSUB-15 Connectors, -10°C to 55°C |
CRFX/BR2-4-ET | 4 Analog Inputs, DSUB-15 Connectors, -40°C to 85°C |
imc CRONOS flex, BR2-4 Datasheet Datasheet |
imc Company Brochure Brochure |
imc_CRONOS-series_Manual Manual |
imc CRONOS, Getting Started Manual Manual |
- Rugged Metal Housing
- 2 Channel input Screw terminals with sensor excitation.
- Inputs may include Vdc, Vac, ma, RTDs, Thermocouples (TC) and IEPE (ICP) sensors
- Screw Terminals with labels specific to each connector
- Cable compression fitting
- Quick Delivery in North America from Inventory
- imc CRONOSflex Base Unit
- 8/16 Digital Inputs, 4 Encoder Inputs (Optional)
- 8 Digital Outputs, 4 Analog Outputs (Optional)
- 1 Gbit Ethernet TCP/IP
- Multipurpose Data Acquisition
- Onboard Computation & Control Logic
- TCP/IP Ethernet Interface for PC Connectivity
- Onboard Flash, Optional Hard Drive Storage and/or Network Storage
Family | imc CRFX |
Unit Type | Base , Standalone |
Max Throughput | 2000 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
- imc CRONOSflex Base Unit
- 8/16 Digital Inputs, 4 Encoder Inputs (Optional)
- 8 Digital Outputs, 4 Analog Outputs (Optional)
- Multipurpose Data Acquisition
- Onboard Computation & Control Logic
- TCP/IP Ethernet Interface for PC Connectivity
- Onboard Flash, Optional Hard Drive Storage and/or Network Storage
- Standalone Operation & Power-Failure Control Logic
Family | imc CRFX |
Unit Type | Base , Standalone |
Max Throughput | 400 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
- Graphical User Interface ease of design capabilities
- Imc Hardware configuration and administration
- 3rd Party Hardware Interface available
- Visualization and Analysis of measured data
- Efficient trigger logic for Automated Data Acquisition & Control
- Real-time analysis and results captured and display
- Automated Test Sequence & Control options
- Complete Real-Time Test Automation
- imc CRONOSflex Universal Measurement Amplifier
- 4 Analog Input Channels
- Galvanically Isolated for Votlage, Current & Thermocouple
- Channel-wise, Individually Configurable Sensor & Bridge Supply
- Pt100 & Pt1000 Supported
- Internal Quarter-Bridge Completion of 120, 350 & 1000 ohms
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, Strain Gauge, ICP, Thermocouple/RTD |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex Differential Measurement Module
- 8 Analog Inputs
- Channel-wise Isolated, Galvanically-separated Inputs
- Finely Adjustable Input Voltage Range (±5 mV to ±50 V)
- Each Channel with its Own Adjustable Filter & Simultaneous A/D Converter
- Supports imc Plug & Measure
- 40kHz bandwidth, 100,000 samples per second (4 to 20 Chns)
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, ICP, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex Audio Measurement Module
- 4 Analog Input Channels, Isolated
- Per-Channel Galvanic Isolation
- Robust & Feedback-Free Signal Acquisition
- Large Signal-to-Noise Ratio
- Low Signal Distortion
- High-Precision Measurements Over Broad Voltage Ranges
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, ICP |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex HV Isolated Measurement Module
- 8 Analog Input Channels
- Each Channel Galvanically Isolated, Channel-to-Channel and Channel-to-Ground
- High Signal Bandwidth
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex High Voltage & Current Measurement Module
- 4 Analog Input Channels, Isolated
- Measurement of up to 600 Vrms (CATIII)/ 1000Vrms (CATII)
- Phase Accuracy Better than 1° for measurements of up to the 50th Harmonic of 50/60 Hz Line Voltage
- Input Ranges from ±1000 V to 2.5 V, Selectable per Channel
- Direct Support for Use of Rogowski Coils
- Amplitude & Phase Response of Current Probes Recorded in TEDS, Used During Measurement
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, High Voltage/Current |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |