CRFX/QI-4, imc CRONOSflex Module
- imc CRONOSflex Charge- & Audio Measurement Module
- 4 Analog Input Channels
- Per-Channel Galvanic Isolation
- Charge Measurement with Low Drift Over Time, for Quasi-Static Measurements
- Low Signal Distortion
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage |
ICP | |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
24-bit | |
Min Temperature | -10 °C |
-40 °C | |
Max Temperature | 55 °C |
85 °C | |
IP Rating | IP20 |
CRFX/QI-4 | 4 Analog Inputs, BNC Input Connectors, -10°C to 55°C |
CRFX/QI-4-ET | 4 Analog Inputs, BNC Input Connectors, -40°C to 85°C |
imc CRONOS flex, QI-4 Datasheet Datasheet |
- imc CRONOSflex Base Unit
- 8/16 Digital Inputs, 4 Encoder Inputs (Optional)
- 8 Digital Outputs, 4 Analog Outputs (Optional)
- 1 Gbit Ethernet TCP/IP
- Multipurpose Data Acquisition
- Onboard Computation & Control Logic
- TCP/IP Ethernet Interface for PC Connectivity
- Onboard Flash, Optional Hard Drive Storage and/or Network Storage
Family | imc CRFX |
Unit Type | Base , Standalone |
Max Throughput | 2000 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
- Graphical User Interface ease of design capabilities
- Imc Hardware configuration and administration
- 3rd Party Hardware Interface available
- Visualization and Analysis of measured data
- Efficient trigger logic for Automated Data Acquisition & Control
- Real-time analysis and results captured and display
- Automated Test Sequence & Control options
- Complete Real-Time Test Automation
- Data source and file format management
- Multi-faceted visualization
- Comprehensive data analysis with function assistant
- Report creation
- Quick processing of large data sets: 64 bit technology
- Automated macro-supported work flow
- Project oriented work approach
- Synchronize measurement data with maps or videos
- imc CRONOSflex Audio Measurement Module
- 4 Analog Input Channels, Isolated
- Per-Channel Galvanic Isolation
- Robust & Feedback-Free Signal Acquisition
- Large Signal-to-Noise Ratio
- Low Signal Distortion
- High-Precision Measurements Over Broad Voltage Ranges
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, ICP |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex Universal Measurement Amplifier
- 4 Analog Input Channels
- Galvanically Isolated for Votlage, Current & Thermocouple
- Channel-wise, Individually Configurable Sensor & Bridge Supply
- Pt100 & Pt1000 Supported
- Internal Quarter-Bridge Completion of 120, 350 & 1000 ohms
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, Strain Gauge, ICP, Thermocouple/RTD |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex High Voltage & Current Measurement Module
- 4 Analog Input Channels, Isolated
- Measurement of up to 600 Vrms (CATIII)/ 1000Vrms (CATII)
- Phase Accuracy Better than 1° for measurements of up to the 50th Harmonic of 50/60 Hz Line Voltage
- Input Ranges from ±1000 V to 2.5 V, Selectable per Channel
- Direct Support for Use of Rogowski Coils
- Amplitude & Phase Response of Current Probes Recorded in TEDS, Used During Measurement
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, High Voltage/Current |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex High Voltage Measurement Module
- 4 Analog Input Channels, Isolated
- Input Ranges from 1000 V to 2.5 V, Selectable per Channel
- Measurement of Categories 600 V (CATIII)/ 1000 V (CATII)
- Phase Accuracy Better than 1° for Measurements up to the 50th Harmonic of 50/60 Hz Line Voltage
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, High Voltage/Current |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex Dynamic Strain Gauge Module
- 8 Analog Input Channels
- Very High Signal Bandwidth of up to 48 kHz
- Software Selectable Quarter-Bridge Completion Between 120 - 350 ohms
- Graphical Configuration Wizard to Set Strain Gauge Bridges
- Supports imc Plug & Measure
- High-Density DSUB Terminal Connection Available
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, Strain Gauge, ICP |
Analog Inputs | 8 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |