µ-CANSAS-HUB4, imc CANSAS Base Unit
- imc CANSAS Base Unit
- Up to 4 µ-CANSAS 1-Channel-Modules, Isolated
- Cast Aluminum Housing
- Power Supply via CAN-Bus Terminal
- Automatic Self-Start at Power-On
- Shock Resistance
Family | imc CANSAS |
Unit Type | Base |
Field Interface | CANbus |
Communication | CANbus |
Min Temperature | -40 °C |
Max Temperature | 120 °C |
µ-CANSAS-HUB4 Datasheet Datasheet |
imc Company Brochure Brochure |
imc_CANSAS_Brochure Brochure |
- imc BUSDAQ-X CAN-Datalogger
- 2-6 CAN-nodes, 8 on Request, Isolated
- 8 Digital I/O, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
Family | imc CANSAS |
Unit Type | Base , Standalone |
Digital Inputs | 4 |
Digital Outputs | 4 |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
- Autonomous operation without PC supported, self-start (timer, absolute time)
- Integrated real-time signal analysis, open and closed loop control with imc Online FAMOS
- Provides 2 to 12 CAN/CAN FD nodes depending on selected housing size
- Handles a variety of protocols such as CCP, XCP, KWP2000, OBD-2, UDS, DiagOnCAN, ...
- Wide operating temperature range from -40 °C to +85 °C
- Trigger, real-time data processing, internal data storage
- GPS position detection
- Autonomous operation with self-start capability (wake-up on CAN)
Family | imc CANSAS |
Unit Type | Base , Standalone |
Input Type | Digital |
Digital Inputs | 16 |
Field Interface | CANbus |
Resolution | 16-bit |
- imc BUSLOG CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | CANbus |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
- imc BUSDAQ-2 CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
- µ-CANSAS-V1, imc CANSAS Differential Amplifier for Voltage
- 1 or 4 Analog Input Channels
- Galvanically Isolated Channels
- Ideal for Voltage Measurement
- 24-bit A/D-Conversion
- Extremely Robust
- Configurable Baud Rate up to 1 MBit/s
- Simultaneous Sampling of All Channels
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage |
Analog Inputs | 1, 4 |
Max Bandwidth | 840 Hz |
Max Sample Rate | 2 kHz |