CANSAS-SCI8, imc CANSAS Module
- imc CANSAS Module for Voltage, Current & Temperature
- 8 or 16 Analog Input Channels
- Measurement Ranges & Sampling Rates Set per Channel in Steps of 1, 2, 5
- Supports imc Plug & Measure TEDS
- Simultaneous Sampling of All Channels
- Synchronization of CANSAS Modules with CAN Logger
- Mechanically Robust
- Self-Start at Power-On
- Integrated DSP for Online Processing
Family | imc CANSAS |
Unit Type | Module |
Standalone | |
Input Type | Voltage |
Current | |
Thermocouple/RTD | |
Analog Inputs | 16 |
Max Bandwidth | 42 Hz |
Max Sample Rate | 1 kHz |
Resolution | 16-bit |
Communication | CANbus |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
IP Rating | IP20 |
IP40 | |
IP65 |
CANSAS-SCI8 | 8 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, IP40 |
CANSAS-L-SCI8 | 8 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, Long Model, IP40 |
CANSAS-L-SCI8-2T | 8 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, Long Model, IP40 |
CANSAS-K-SCI8 | 8 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-K-SCI8-BNC | 8 Analog Inputs, BNC Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-K-SCI8-2T | 8 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-SL-SCI8-D | 8 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Sealed Housing, IP65 |
CANSAS-SL-SCI8-L | 8 Analog Inputs, LEMO Signal Conn, LEMO CAN Conn, Sealed Housing, IP65 |
CANSAS-SL-SCI8-2T | 8 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Sealed Housing, IP65 |
CANSAS-SCI16 | 16 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, IP40 |
CANSAS-L-SCI16 | 16 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, Long Model, IP40 |
CANSAS-L-SCI16-2T | 16 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Aluminum Housing, Long Model, IP40 |
CANSAS-K-SCI16 | 16 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-K-SCI16-BNC | 16 Analog Inputs, BNC Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-K-SCI16-2T | 16 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Cassette Housing, IP20 |
CANSAS-SL-SCI16-D | 16 Analog Inputs, DSUB-15 Signal Conn, DSUB-9 CAN Conn, Sealed Housing, IP65 |
CANSAS-SL-SCI16-L | 16 Analog Inputs, LEMO Signal Conn, LEMO CAN Conn, Sealed Housing, IP65 |
CANSAS-SL-SCI16-2T | 16 Analog Inputs, 2-pin Thermo Signal Conn, DSUB-9 CAN Conn, Sealed Housing, IP65 |
CANSAS-SCI8 Datasheet Datasheet |
imc Company Brochure Brochure |
imc_CANSAS_Brochure Brochure |
- Rugged Metal Housing
- 4 Channel input Screw terminals
- Inputs may include Vdc, Vac, ma, RTDs, Thermocouples (TC) and IEPE (ICP) sensors
- Screw Terminals with labels specific to each connector
- Cable compression fitting
- Quick Delivery in North America from Inventory
- imc BUSDAQ-2 CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
- imc BUSDAQ-X CAN-Datalogger
- 2-6 CAN-nodes, 8 on Request, Isolated
- 8 Digital I/O, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
Family | imc CANSAS |
Unit Type | Base , Standalone |
Digital Inputs | 4 |
Digital Outputs | 4 |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
- imc BUSLOG CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | CANbus |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
- Graphical User Interface ease of design capabilities
- Imc Hardware configuration and administration
- 3rd Party Hardware Interface available
- Visualization and Analysis of measured data
- Efficient trigger logic for Automated Data Acquisition & Control
- Real-time analysis and results captured and display
- Automated Test Sequence & Control options
- Complete Real-Time Test Automation
- imc CANSAS Module for Voltage, Current & Temperature
- 16 Analog Input Channels
- Simultaneous Sampling of All Channels
- Synchronization of CANSAS Modules with CAN Logger
- Mechanically Robust
- Self-Start at Power-On
- Supports imc Plug & Measure
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 16 |
Max Bandwidth | 28 Hz |
Max Sample Rate | 500 Hz |
- imc CANSAS Differential Amplifier for Current, Voltage & Temperature
- 8 Analog Input Channels, Isolated
- Simultaneous Sampling of All Channels
- Synchronization of imc CANSAS Modules with CAN Logger
- Support imc Plug & Measure
- Mechanically Robust
- Self-Start at Power-On
- Connectors for V, ma, RTD or Temperature sensors under "Related" tab
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 440 Hz |
Max Sample Rate | 1 kHz |
- imc CANSAS Universal Module
- 8 Input Channels
- Simultaneous Sampling of All Channels
- Synchronization of CANSAS Modules with CAN Logger
- Mechanically Robust
- Integrated DSP for Online Processing
- Self-Start at Power-On
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage, Current, Strain Gauge, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 200 Hz |
Max Sample Rate | 1 kHz |
- imc CANSAS Differential Amplifier for Current, Voltage & Temperature
- 8 Analog Input Channels
- Simultaneous Sampling of All Channels
- Mechanically Robust
- Synchronizing of CANSAS Modules with CAN Logger
- Self-Start on Power-On
- Connectors for V, ma, RTD or Temperature sensors under "Related" tab
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 200 Hz |
Max Sample Rate | 100 Hz |
- imc CANSAS Bridge Amplifier Module
- 8 Analog Input Channels
- Simultaneous Sampling of All Channels
- Synchronization of CANSAS Modules with CAN Logger
- Mechanically Robust
- Self-Start at Power-On
- Connectors for V, ma, (1/4, 1/2 or full bridge) Strain Gauge sensors under "Related" tab
Family | imc CANSAS |
Unit Type | Module, Standalone |
Input Type | Voltage, Strain Gauge |
Analog Inputs | 8 |
Max Bandwidth | 200 Hz |
Max Sample Rate | 1 kHz |