MSX-E3017, Ethernet Force-Distance System
- 1 Counter Input
- 4 Analog Inputs, Differential
- 24-bit Resolution
- Optical Isolation
- 2 Digital I/O, 24 V
- 24 V Digital Trigger Input
- Simultaneous Sampling of All Channels
- 64 MB Onboard SDRAM for Data Storage
- Robust Metal Housing
- Easy Configuration: Easy Mode
With the MSX-E3017 system, you can effect force-distance measurements in 2 different ways: in auto-refresh mode or sequence mode. The acquisition can be done depending on a position or on time.
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Voltage |
Current | |
Digital | |
Frequency | |
Encoder | |
Analog Inputs | 4 |
Digital Inputs | 2 |
Digital Outputs | 2 |
Field Interface | Sync Pulse |
Resolution | 24-bit |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
IP Rating | IP65 |
The client (e.g. PC, server, PLC, …) reads the acquired values asynchronously to the acquisition through socket connection, SOAP or Modbus function.
In sequence mode, a list of channels is acquired. Thereby, the single measurement rows are stored one after another. The client receives the acquired values asynchronously to the acquisition through a socket connection. In the sequence mode, the measurement values are read in chronological order, this means the oldest values are read first. The acquisition can be effected continuously, with or without delay or in combination with a hardware or synchro trigger.
MSX-E3017 Ethernet Force-Distance System Datasheet |
- 1 Counter Input
- 4 Strain Gauge Inputs, Differential
- 24-bit Resolution
- Optical Isolation
- 2 Digital I/O, 24 V
- Easy Configuration: Easy Mode
- 64 MB Onboard SDRAM for Data Storage
- Robust Metal Housing
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Strain Gauge, Digital, Frequency, Encoder |
Analog Inputs | 4 |
Digital Inputs | 2 |
Digital Outputs | 1 |
- 8 Analog Input Channels
- Half-Bridge, LVDT, Mahr or Knaebel Inputs
- 1 Incremental Counter Input
- 1 Temperature Input
- Simultaneous Sampling of up to 8 Channels
- Optical Isolation 1000 V
- 24 V Digital Trigger Input
- Robust Metal Housing
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Voltage, Thermocouple/RTD, Frequency, Encoder |
Analog Inputs | 9 |
Digital Inputs | 1 |
Field Interface | Sync Pulse |
- 16/8/4 Analog Input Channels
- Half-Bridge, LVDT, Mahr or Knaebel Inputs
- 24-bit Resolution
- Optical Isolation 1000 V
- Digital Output with Compare Logic, 24 V (option)
- 24 V Digital Trigger Input
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Voltage |
Analog Inputs | 4, 8, 16 |
Field Interface | Sync Pulse |
Resolution | 24-bit |
- 8 or 2 Differential/Single-Ended Inputs
- 8 or 2 Current Sources for IEPE/ICP Sensors
- 24-bit Resolution
- Simultaneous Sampling of Channels
- 24 V Digital Trigger Input
- 64 MB Onboard SDRAM for Data Storage
- Robust Metal Housing
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Voltage, ICP |
Analog Inputs | 2, 8 |
Field Interface | Sync Pulse |
Resolution | 24-bit |
- 16/8/4 Differential Inputs
- For Thermocouples or RTD
- 24-bit Resolution
- Simultaneous Sampling of up to 8 Channels
- 24 V Digital Trigger Input
- 64 MB Onboard SDRAM for Data Storage
- Robust Metal Housing
Family | ADDI-DATA MSX |
Unit Type | Standalone |
Input Type | Thermocouple/RTD |
Analog Inputs | 4, 8, 16 |
Field Interface | Sync Pulse |
Resolution | 24-bit |