CRSL/ICPU-16, imc CRONOS-SL Chassis Module
- imc CRONOS-SL ICP Amplifier
- 16 Analog Input Channels
- Voltage or ICP-Sensor Inputs
- Overvoltage Protection
- Occupies 4 Slots
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage |
ICP | |
Analog Inputs | 16 |
Max Bandwidth | 6.6 kHz |
Max Sample Rate | 20 kHz |
Resolution | 16-bit |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
IP Rating | IP65 |
imc Company Brochure Brochure |
CRONOS ICPU-16 Datasheet Datasheet |
- imc CRONOS-SL, Portable Chassis
- 2 Module Slots
- 16 Channels
- Onboard Computation & Control Logic
- Onboard Flash Storage
- 100 MBit Ethernet
- Self-Start After Power Failure
- Extremely Robust
Family | imc CRONOS-SL |
Unit Type | Chassis |
Slots | 2 |
Max Throughput | 400 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
- imc CRONOS-SL Portable Chassis
- 4 Module Slots
- 32 Channels
- Onboard Computation & Control Logic
- Onboard Flash Storage
- 100 MBit Ethernet
- Self-Start After Power Failure
- Extremely Robust
Family | imc CRONOS-SL |
Unit Type | Chassis |
Slots | 4 |
Max Throughput | 400 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
- Graphical User Interface ease of design capabilities
- Imc Hardware configuration and administration
- 3rd Party Hardware Interface available
- Visualization and Analysis of measured data
- Efficient trigger logic for Automated Data Acquisition & Control
- Real-time analysis and results captured and display
- Automated Test Sequence & Control options
- Complete Real-Time Test Automation
- Analysis platform for sound & vibration testing with imc measurement systems
- Analyzers based on standardized test routines
- Acoustics in the context of a universal measuring system
- Additional synchronized data acquisition of signals such as force, pressure, strain, temperature, GPS, etc - for analsyses and correlations
- CAN vehicle bus integration
- Data source and file format management
- Multi-faceted visualization
- Comprehensive data analysis with function assistant
- Report creation
- Quick processing of large data sets: 64 bit technology
- Automated macro-supported work flow
- Project oriented work approach
- Synchronize measurement data with maps or videos
- imc CRONOS-SL Fast Isolated Amplifier
- 16 Analog Input Channels, Differential
- Voltage or Current Inputs
- ICP-Sensor Inputs (option)
- Surge Protection
- Supports imc Plug & Measure
- Occupies 2 Slots
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, ICP |
Analog Inputs | 16 |
Max Bandwidth | 6.6 kHz |
Max Sample Rate | 20 kHz |
- imc CRONOS-SL Bridge Amplifier
- 4 Analog Input Channels
- Bridge Inputs
- DC & Carrier Frequency Mode (5 kHz)
- Supports Lead Wire Compensation with Single & Dual Sense Line Configurations
- Symmetric Bridge Supply of 1 V, 2.5 V, 5 V; DC & AC Mode
- Software Selectable Quarter Bridge Complete 120 & 350 ohms Switchable
- Cable Breakage Recognition
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Strain Gauge, ICP |
Analog Inputs | 4 |
Max Bandwidth | 8.6 kHz |
Max Sample Rate | 20 kHz |
- imc CRONOScompact ICP Amplifier
- 16 Analog Input Channels
- Voltage or ICP-Sensor Inputs
- Overvoltage Protection
- Occupies 4 Slots
Family | imc CRONOScompact |
Unit Type | Module |
Input Type | Voltage, ICP |
Analog Inputs | 16 |
Max Bandwidth | 6.6 kHz |
Max Sample Rate | 20 kHz |
- imc CRONOScompact Fast Isolated Amplifier
- 16 Analog Input Channels, Differential
- Voltage or Current Inputs
- ICP-Sensor Inputs (option)
- Surge Protection
- Supports imc Plug & Measure
- Occupies 2 Slots
Family | imc CRONOScompact |
Unit Type | Module |
Input Type | Voltage, Current, ICP |
Analog Inputs | 16 |
Max Bandwidth | 6.6 kHz |
Max Sample Rate | 20 kHz |
- imc CRONOS-SL Isolated Differential Amplifier
- 8 Analog Input Channels, Isolated
- Voltage, Current, Temperature or ICP-Sensor Inputs
- 16-bit Resolution
- Overvoltage Protection
- Occupies 1 Slot
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, ICP, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |