Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

2169, AC Current Panel Meter

The 2169 AC current panel meter is intended for AC applications where there is considerable waveform distortion from nonlinear loading. The input is AC-coupled to read only the AC component, such as ripple on a power supply.
2169, AC Current Panel Meter
2169, AC Current Panel Meter
Features:
  • Panel Mount Indicator
  • AC Current Analog Inputs
  • Protection Class: IP65
  • RS-232/485 or BCD Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
Manufacturer:  Daytronic Corp.
Quote
Datasheet
Specifications
Models & Accessories
Downloads
Similar Products
2169 - Specifications
Input TypeAC Current
No. of Inputs1
Excitation5 V DC
10 V DC
24 V DC
Output TypeDC Voltage
DC Current
Relay
InterfaceRS-232/485
Supply Power9 - 32 V DC
8 - 28 V AC
85 - 250 V AC
IP RatingIP65
2169 - Models & Accessories
Models
2169-2 2 mA AC Current Range
2169-20 20 mA AC Current Range
2169-200 200 mA AC Current Range
2169-55 A AC Current Range
2169 - Downloads
2169 - Similar Products
  • Panel Mount Indicator
  • Quadrature Encoder Inputs
  • Protection Class: IP65
  • RS-232/485 Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
  • Overvoltage Protection
Input Type
Encoder
No. of Inputs
1
Excitation
5 V DC,
10 V DC,
24 V DC
Output Type
DC Voltage,
DC Current,
Relay
Interface
RS-232/485
Supply Power
9 - 32 V DC,
8 - 28 V AC,
85 - 250 V AC
  • Panel Mount Indicator
  • DC Voltage Analog Inputs
  • Protection Class: IP65
  • RS-232/485 or BCD Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
  • Overvoltage Protection
Input Type
DC Voltage
No. of Inputs
1
Excitation
5 V DC,
10 V DC,
24 V DC
Output Type
DC Voltage,
DC Current,
Relay
Interface
RS-232/485
Supply Power
9 - 32 V DC,
8 - 28 V AC,
85 - 250 V AC
  • Panel Mount Indicator
  • DC Current Analog Inputs
  • Protection Class: IP65
  • RS-232/485 or BCD Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
  • Overcurrent Protection
Input Type
DC Current
No. of Inputs
1
Excitation
5 V DC,
10 V DC,
24 V DC
Output Type
DC Voltage,
DC Current,
Relay
Interface
RS-232/485
Supply Power
9 - 32 V DC,
8 - 28 V AC,
85 - 250 V AC
  • Panel Mount Indicator
  • Process Signal Inputs
  • Protection Class: IP65
  • Custom Scaling (Model 2162X)
  • RS-232/485 Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
Input Type
DC Current
No. of Inputs
1
Excitation
5 V DC,
10 V DC,
24 V DC
Output Type
DC Voltage,
DC Current,
Relay
Interface
RS-232/485
Supply Power
9 - 32 V DC,
8 - 28 V AC,
85 - 250 V AC
  • Panel Mount Indicator
  • AC Voltage Analog Inputs
  • Protection Class: IP65
  • RS-232/485 Interface (Option)
  • Isolated Relay Output (Option)
  • Isolated Analog Output (Option)
  • Low AC/DC Power Supply (Option)
Input Type
AC Voltage
No. of Inputs
1
Excitation
5 V DC,
10 V DC,
24 V DC
Output Type
DC Voltage,
DC Current,
Relay
Interface
RS-232/485
Supply Power
9 - 32 V DC,
8 - 28 V AC,
85 - 250 V AC
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us