Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

5M40, Frequency Conditioner

The Model 5M40 DIN conditioner is used with conventional frequency-generating transducers, such as tachometer pickups, turbine flow meters, transistor or logic-circuit drivers, and “zero velocity” (true digital output) sensors. The 5M40...
5M40, Frequency Conditioner
5M40, Frequency Conditioner
Features:
  • Selectable frequency ranges up to 32 kHz
  • Selectable input threshold levels
  • Capacitive coupling for magnetic pickup inputs
  • Selectable filtering on the amplified signal output
  • Effective signal isolation & ESD protection
Manufacturer:  Daytronic Corp.
Quote
Datasheet
Description
Specifications
Downloads
Similar Products
5M40 - Description
The Model 5M40 DIN conditioner is used with conventional frequency-generating transducers, such as tachometer pickups, turbine flow meters, transistor or logic-circuit drivers, and “zero velocity” (true digital output) sensors. The 5M40 will accept sine, square and irregular waveform inputs, plus TTL. The 5M40 delivers filtered analog output of 5 Vdc, 10 Vdc or 4-20mA, selectable. Exceptional signal stability and accuracy over an unusually wide dynamic range—down to 1.0 % of full scale.

In addition to its standardized pulse-averaging circuit, the Model 5M40 incorporates years of design strategies for frequency conditioning in factory environments that require high dynamic response even at low frequencies. The 5M40 Module will accept signals from 50mV to 240 Volts RMS with selectable input sensitivity settings for a wide range of frequency wave shapes— floating or grounded, producing a stable analog output signal proportional to the input frequency. The 5M40 may be used with magnetic pickups, Hall Effect sensors. The 5M40 offers eight selectable full scale input frequency ranges from 250 Hz to 32 kHz. These full scale ranges will provide an analog output of 5 Vdc or 10 Vdc or 4-20mA which has been conditioned through a selectable three - pole filter. This maintains a stable analog signal from 1% to 100% of the input frequency range selected; resulting in a dynamic, amplified signal that is not “time based” dependent for applications requiring responsive monitoring or control which traditional digital counters and “1/t” based units lack.

Capacitive shunting (or “coupling”) of 0.1 microFarads is provided for magnetic pickup inputs, to eliminate false triggering by signal noise. For waveform inputs from approximately 5 Hz to 32 kHz, a “Smart Schmitt” trigger—in conjunction with a variable-sensitivity amplifier—adapts to signal amplitudes from 50 mV to 250 V, thus ensuring reliable triggering for all input levels.
5M40 - Specifications
Input TypeFrequency
# of Inputs1
Output Type0 - 5 V DC
0 - 10 V DC
4 - 20 mA
Max Bandwidth125 Hz
Excitation10 V DC
IsolationYes
Supply Power12 - 28 V DC
5M40 - Downloads
5M40 - Similar Products
  • High Accuracy
  • For Switch Cabinet Assembly, Width 23 mm, only
  • Direct Connection to PLC
  • Long Input Lead from GM 40 to Evaluation possible
  • Easy to operate
  • Voltage or Current Output
  • DIN Rail Mount
  • Rating: IP20
Input Type
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
4 - 20 mA
Max Bandwidth
1 kHz,
5 kHz,
10 kHz
Excitation
5 V DC,
10 V DC
Isolation
Yes
  • Precisely regulated excitation
  • Chopper-stabilized low-drift amplification
  • Selectable low-pass active filtering
  • Front panel setup configuration & calibration
  • Wide input range from 50 mv to 50 Vdc FS & 4-20mA
Input Type
±50 mV to ±50 V DC,
4 - 20 mA
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
4 - 20 mA
Max Bandwidth
1 kHz
Excitation
10 V DC
Isolation
Yes
  • Strain Gauge & Potentiometer Input Amplifier
  • 50 V Continuous Isolation
  • Accuracy: ± 0.05%
  • DIN Rail Mounted
  • In-Line Amplifier (Option)
  • Aluminum Housing
  • Protection Class: IP40
Input Type
0 - 10 mV DC,
0 - 100 mV DC,
0 - 1 V DC,
0 - 10 V DC,
±10 V DC,
Potentiometer,
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
1 kHz,
4 kHz
Excitation
2.5 V DC,
5 V DC,
10 V DC
Isolation
Yes
  • DIN Rail mount, LVDT Amplifier
  • Compatible with any standard RDP LVDT (without integral electronics)
  • Compatible with LIN & PY When fitted with two 1k Ohm bridge completion resistors (Does not provide analogue voltage linearisation for PY)
  • Compatible with most LVDTs from any manufacturer
  • Screw terminal connections
  • Simple controls for gain and zero adjustment
  • Input zero switch
  • Signal overload indicator
Input Type
LVDT
# of Inputs
1
Output Type
0 - 10 V DC,
±10 V DC,
4 - 20 mA
Max Bandwidth
250 Hz
Excitation
1 V AC,
3 V AC
Isolation
Yes
  • T401 / T402 provide an analog output of 4(0)-20ma or 2(0)-10 Vdc
  • T411 and T412 models are panel Mount display versions
  • Isolated input with automatic trigger level adjustment
  • 2 limit set points with programmable hysteresis
  • Windows Explorer configuration software allows:
  • • Quick and easy configuration of all operating parameters
  • • Unit interrogation of identity and parameters
  • • PC display of current measurement and relay status
Interface
RS-232
Input Type
Frequency
# of Inputs
1
Output Type
0 - 10 V DC,
2 - 10 V DC,
0 - 20 mA,
4 - 20 mA
Isolation
Yes
Supply Power
10 - 36 V DC