- Integration via PROFIBUS, PROFINET or EtherNet/IP
- Automatic sensor recognition from burster TEDS
- 3.5" color touch screen display
- 16 measurement programs
- Rapid data logging on USB flash drive
- New evaluation elements (trapezoid window and thresholds)
- User-configurable I/Os and 6 real-time switching signals
- Smart auto setup for evaluation elements
- Handles worker, admin and identification data
- Up to 50 most recent measurements available for display and analysis
- Records and evaluates a forward and return curve
- Live sensor values provided at the Fieldbus interface
- Synchronous logging of measurement data using DigiControl PC software for multichannel applications
DIGIFORCE 9311 is the new standard in efficient quality control. The pioneering force/displacement controller delivers rapid, precise evaluation results for applications that demand both high quality and high productivity. The smart performance features and intelligent hardware make test equipment quicker to set up, easier to use and capable of automatic integration in modern production systems.
The DIGIFORCE 9311 monitors processes in which precisely defined functional relationships need to be demonstrated between two measured quantities of the process. For instance when recording and monitoring processes such as press-insertion, joining, riveting, stamping or caulking, reliable quality control depends on synchronous and high-speed acquisition of measured values combined with analysis based on versatile evaluation elements. DIGIFORCE 9311 provides the modern platform you need for this task, offering the choice of Fieldbus interfaces, including PROFINET, PROFIBUS and EtherNet/IP, to let you integrate the test setup in your particular control environment.
The DIGIFORCE 9311 uses burster TEDS to provide automatic sensor recognition. This feature automatically reads an electronic datasheet stored in the sensor so that the relevant data can be used in the measurement-channel configuration. DIGIFORCE 9311 offers data logging capabilities for recorded measurements and curves. The DigiControl PC software provides support with an automatic data logging mode that runs in parallel with production. There is also the option for high-speed data acquisition on a USB flash drive.
burster 9311 DigiForce Monitor Controller Introduction Video
- this video illustrates the standard features of the 9311. .
- the Ethernet Communication & USB Data Collection Port. .
- the Feildbus Ports, Ethrenet IP, Profibus and ProfiNet. .
- the Menu structure & ease of navigation through the setup
Input Type | DC Voltage |
Potentiometer | |
Strain Gauge | |
ICP | |
# of Inputs | 2 |
Max Sample Rate | 5 kHz |
Evaluation | Threshold |
Envelopes | |
Windows | |
Interface | Digital I/O |
Profibus | |
Profinet | |
Ethernet/IP | |
Communication | Ethernet |
USB |
9311-V0000 | Touch Screen Display; std inputs mV & Vdc; outputs Dig I/O, USB & Ethernet TCP/IP |
9311-V0002 | Touch Screen Display; std inputs mV & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & PROFIBUS |
9311-V0003 | Touch Screen Display; std inputs mV & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & PROFINET |
9311-V0004 | Touch Screen Display; std inputs mV & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & EtherNet/IP |
9311-V0100 | Touch Screen Display; inputs Piezo & Vdc; outputs Dig I/O, USB & Ethernet TCP/IP |
9311-V0102 | Touch Screen Display; inputs Piezo & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & PROFIBUS |
9311-V0103 | Touch Screen Display; inputs Piezo & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & PROFINET |
9311-V0104 | Touch Screen Display; inputs Piezo & Vdc; outputs Dig I/O, USB, Ethernet TCP/IP & Ethernet/IP |
9311-V2000 | DigiForce X-Y Press Force Controller; Xchn: ±5V or ±10V, Ychn: ±2 … ±40 mV/V, ±5V, ±10V, 9x control inputs; No Touch Screen LCD Graphic Display, 12 Digital Outputs; 100-240VAC power; Ethernet & USB communication |
9310 | Previous Generation DigiForce |
burster 9311 DigiForce Monitor Controller Ethernet TCP/IP communication setup video.
This video discusses the initial configuration of the standard Ethernet communication port,
This may be a prerequisite for data collection from the 9311 device, the data evaluation and
the development of the Curve Evaluation criteria, the Data Collection Windows & Acceptance
/ Reject Tolerance Windows.
burster 9311 DigiForce X & Y Channel input setup and Calibration,
- this video explores the selection of input type, excitation, sensitivity, etc.
- these inputs are typically X = Displacement & Y = Force .
- these inputs could also be X = Angle & Y = Torque .
- this steps you through the full scale gain & offset for a Load Cell & LVDT .
burster 9311 DigiForce Monitor Controller Input Channel Configuration
- this video illustrates the selection of input type, sensitivity, teach-in, etc. .
- these inputs are typically X = Potentiometer & Y = Strain Gauge Force Sensor. .
- these inputs could also be X = Angle Pot or Encoder & Y = Rotary Torque Sensor.
- this steps you through the full scale gain & offset for a Load Cell & LVDT. .
burster 9311 DigiForce Monitor Controller Setup of the Measurement Mode
burster 9311 DigiForce Monitor Controller Ethernet IP for Control & Data Collection
- this video illustrates the selection of input type, sensitivity, teach-in, etc. .
- these inputs are typically X = Potentiometer & Y = Strain Gauge Force Sensor. .
- these inputs could also be X = Angle Pot or Encoder & Y = Rotary Torque Sensor.
- this steps you through the full scale gain & offset for a Load Cell & LVDT. .
burster 9311 DigiForce Monitor Controller Configuring an Evaluation Curve Window
- this video illustrates the collection of a X - Y Signature Curve. .
- once data is collected, the curve is graphically illustrated for analysis. .
- Tolerance Bands or Windows can be activated around the good part data. .
- Specific Data within a Window can be transferred to the PLC via a Fieldbus. .
burster 9311 DigiForce Monitor Controller Curve Window Evaluation Setup
- this video illustrates the collection of a Data Signature Curve. .
- once data is collected, the curve is graphically illustrated for analysis. .
- Tolerance Bands or Windows can be activated around the good part data. .
- The Data within a Data Window can be transferred to the PLC via a Fieldbus.
burster 9311 DigiForce Monitor Controller Curve Window Envelope Evaluation Setup for a Signature Analysis
The Video of the standard Curve Window Evaluation Setup is a prerequisite for this video.
This video explores the unique Tolerance Band Curve Window that can be auto-created ,
for the purpose of acceptance and rejection of the Press Operation performed. There is the
possibility of 32 different programs, each can have a unique Tolerance Band Curve Window.
burster 9311 DigiForce Monitor Controller Curve Data Collection of a Signature .
This Video illustrates how to the Collect Data of a standard Curve Window for archiving and
Evaluation Setup. There is the possibility of 32 different programs, each can have a unique
Tolerance Band Curve Window. ,
9311-V000X STP File Drawings |
9311-V010X STP File Drawings |
9311 IN_STROBE Program Change Timing issue Tech Note |
Digiforce 9311 X-Y Controller Datasheet Datasheet |
Digiforce 9307,9311 Overview Brochure |
9311-V000X STP File Drawings |
9311-V010X STP File Drawings |
9311 IN_STROBE Program Change Timing issue Tech Note |
- Tension & Compression
- Accuracy: < ±0.25% F.S.
- Accuracy: Range ≤ 5 N: ±0.1% F.S. (Option)
- Outer Diameter: 54.5mm - 155.0mm
- Height: 16.0mm - 50.0mm
- Overload Protection up to 20 kN (Option)
- Connection: 2m Integral Cable
- Stainless Steel
Type | Pancake |
Application | Tension & Compression |
Full Scale | 112 lbs, 220 lbs, 450 lbs, 1120 lbs, 2200 lbs, 4500 lbs, 11200 lbs, 22000 lbs, 45000 lbs |
Output | 1.5 mV/V |
Precision | ±0.1 % FS, ±0.25 % FS |
Excitation | 10 V DC, 10 V AC |
- Potentiometer
- Rectangular Profile Housing
- Anodized Aluminum Housing
- Connection: 1.0m Integral Cable
- Duration: 10^8 Operations
- Displacement Speed: up to 10m/s
Type | Potentiometer |
Full Scale | 25 mm [0.984"], 50 mm, 75 mm, 100 mm, 150 mm |
Output | Potentiometric |
Non-Linearity | ±0.05 % FS, ±0.10 % FS, ±0.20 % FS |
Resolution | 0.01 mm |
Excitation | 0 - 25 V DC, 0 - 60 V DC |
- Potentiometer
- Rectangular Profile Housing
- Anodized Aluminium Housing
- Connection: 5-pin 9991 Plug Connector
- Durability: 10^8 Operations
Type | Potentiometer |
Full Scale | 10 mm, 25 mm [0.984"], 50 mm, 100 mm, 125 mm, 150 mm |
Output | Potentiometric |
Non-Linearity | ±0.05 % FS, ±0.10 % FS, ±0.20 % FS, ±0.30 % FS |
Resolution | 0.01 mm |
Excitation | 0 - 14 V DC, 0 - 25 V DC, 0 - 50 V DC |
- Multiple Device Curve Display, 1, 2, 4 & 8 devices
- Database supported, for SQL access
- Data Storage to csv file format available
- Network capable for remote data review
- The 9306 has been discontinued and is replaced by 9307.
- There is an upgrade path for the sensors, cable and acceptance/reject criteria.
- There is also updated software for data collection, graphical display and analysis.
Input Type | DC Voltage, Potentiometer, Strain Gauge, ICP, Encoder |
# of Inputs | 2 |
Max Sample Rate | 5 kHz |
Evaluation | Envelopes, Windows |
Interface | Digital I/O, Profibus |
Communication | USB, RS-232 |