imc WAVE, Sound and Vibration Analysis Software
- Analysis platform for sound & vibration testing with imc measurement systems
- Analyzers based on standardized test routines
- Acoustics in the context of a universal measuring system
- Additional synchronized data acquisition of signals such as force, pressure, strain, temperature, GPS, etc - for analsyses and correlations
- CAN vehicle bus integration
With imc WAVE, you are provided with a powerful software platform for noise and vibration analysis. Various analyzers cover a wide range of applications: from acoustical inspections during road tests, structural analyses on the test bench, up to vibration testing.
With imc WAVE, you can quickly and easily solve a wide variety of tasks in sound and vibration analysis. The well guided work flow will lead you step by step through the parameter settings for your specific application. From the device configuration through the microphone calibration procedure up to starting the measurement, imc WAVE offers a simple operating concept.
Spectrum Analyser
- Sound power-level testing
- Octave & 1/3-octave analysis
- Frequency and time weighting
- Vibration analysis
- FFT analysis
Structural Analyzer
- Calculation of transfer functions (magnitude and phase)
- Coherences
- Auto-spectra & DOFs
- Export to Excel or modal analysis software ME Scope
Order Tracking Analyzer
- Order tracking spectra based on measured RPM
- Noise & vibration levels vs. RPM (various classifications)
- Transfer functions vs. time and angle
imc Wave 2022 - News Release Product Note |
imcWAVE Datasheet Datasheet |
imc WAVE Manual Manual |
imcWave Getting Started Manual Manual |
imc Company Brochure Brochure |
imc Wave Brochure |
- imc CRONOSflex Base Unit
- 8/16 Digital Inputs, 4 Encoder Inputs (Optional)
- 8 Digital Outputs, 4 Analog Outputs (Optional)
- 1 Gbit Ethernet TCP/IP
- Multipurpose Data Acquisition
- Onboard Computation & Control Logic
- TCP/IP Ethernet Interface for PC Connectivity
- Onboard Flash, Optional Hard Drive Storage and/or Network Storage
Family | imc CRFX |
Unit Type | Base , Standalone |
Max Throughput | 2000 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
Resolution | 16-bit |
- imc CRONOSflex Audio Measurement Module
- 4 Analog Input Channels, Isolated
- Per-Channel Galvanic Isolation
- Robust & Feedback-Free Signal Acquisition
- Large Signal-to-Noise Ratio
- Low Signal Distortion
- High-Precision Measurements Over Broad Voltage Ranges
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, ICP |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex IEPE/ICP-Measurement Module
- 8 Analog Input Channels, Isolated
- Finely Adjustable Input Voltage Range (From ±5 mV to ±50 V)
- Input Coupling Switchable via Software: DC, AC, AC with Current Supply
- Each Channel with Adjustable Filter & Simultaneous A/D Converter
- Supports imc Plug & Measure
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, ICP |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
Resolution | 16-bit, 24-bit |
- imc CRONOSflex Differential Measurement Module
- 8 Analog Inputs
- Channel-wise Isolated, Galvanically-separated Inputs
- Finely Adjustable Input Voltage Range (±5 mV to ±50 V)
- Each Channel with its Own Adjustable Filter & Simultaneous A/D Converter
- Supports imc Plug & Measure
- 40kHz bandwidth, 100,000 samples per second (4 to 20 Chns)
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, ICP, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex HV Isolated Measurement Module
- 8 Analog Input Channels
- Each Channel Galvanically Isolated, Channel-to-Channel and Channel-to-Ground
- High Signal Bandwidth
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex High Voltage & Current Measurement Module
- 4 Analog Input Channels, Isolated
- Measurement of up to 600 Vrms (CATIII)/ 1000Vrms (CATII)
- Phase Accuracy Better than 1° for measurements of up to the 50th Harmonic of 50/60 Hz Line Voltage
- Input Ranges from ±1000 V to 2.5 V, Selectable per Channel
- Direct Support for Use of Rogowski Coils
- Amplitude & Phase Response of Current Probes Recorded in TEDS, Used During Measurement
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, Current, High Voltage/Current |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOSflex High Voltage Measurement Module
- 4 Analog Input Channels, Isolated
- Input Ranges from 1000 V to 2.5 V, Selectable per Channel
- Measurement of Categories 600 V (CATIII)/ 1000 V (CATII)
- Phase Accuracy Better than 1° for Measurements up to the 50th Harmonic of 50/60 Hz Line Voltage
Family | imc CRFX |
Unit Type | Module |
Input Type | Voltage, High Voltage/Current |
Analog Inputs | 4 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |