MS02-100B, 2 kN (0.1 Ton) Assembly Servo Press
- Force range of 2 kN, (0.1Ton)
- Stroke ranges available up to 100 mm & 200 mm
- Maximum speeds of up to 225 mm/s
- PC independent Force vs. Displacement Signature
- Analysis using:
- o Limits
- o Envelopes
- o Windows
- All popular PLC Interfaces:
- o EthernetIP
- o Digital I/O
- o DeviceNet
- o Profibus
- o CC-Link
- All limits, data and program info can be read and written through the PLC
The Coretec integrated servo press features a ball screw drive mounted on a custom collar load cell for force feedback. The repeatable force, displacement and speed control facilitated by the compact controller performs in process verification, providing added benefits such as early failure detection and scrap reduction.
Don't settle with simple displacement and speed control or tolerate motor current draw approximation.
In addition to superior control, the integrated load cell and encoder can be used to perform Force vs. Distance Signature Analysis, with included PC software for Visualization and Data Collection.
This space-saving design and minimum mounting pitches allow for multi-axis press fitting with less installation time. Over time servo presses will provide cost savings compared to hydraulic presses, as there is less power, and less items to maintain.
Each press is "intelligent", and easily interchangeable when scheduled maintenance is required.
The press tool is equipped with a CPU enabling it to store items such as model numbers and load values in on board memory, thereby eliminating controller mismatch errors.
A specialized language for the servo press has been developed that permits description of complicated motions equivalent to robotic control systems.
The auto program generation provides examples based on your application, with comments generated. Application support will be provides as part of the system supplied by A-Tech Instruments Ltd.
Max Force | 2 kN (0.1 Ton, 450 lbs Force ) |
Max Speed | 225 mm/s |
Stroke | 100 mm |
200 mm | |
Interface | Digital I/O |
ProfiNet | |
DeviceNet | |
EthernetIP | |
CC-Link |
MS02 | |
MS02-100B | 2kN Force Capacity Miniature Servo Press & 100mm Stroke |
MS02-200B | 2kN Force Capacity Miniature Servo Press & 200mm Stroke, built to order |
Instruction Video for CPS Controller Ethernet TCP/IP Communication Setup with a Windows PC
Instruction Video for CPS Controller Ethernet IP Communication Setup with PLC
Instruction Video for Coretec CS Series Servo Press Initialization and Auto Generation Programming using CORETEC CPS-SP Configurator. The procedure is identical for BS/MS series Servo Press Programming which uses BS-SP Configurator.
This video also discusses the Ethernet TCP/IP Communication Setup with the PLC and Manual Operation of the Servo Press Tool. This is similar to setup and communication with ProfiNet communication to & from a PLC.
Instruction Video for Coretec WPS Controller Ethernet TCP/IP communication setup using the Coretec WPS Configuration Software
Instruction Video for Coretec WPS Controller Ethernet IP Feildbus to PLC communication setup using the Coretec WPS Configuration Software
MS02-100 Drawings |
MS02-100 stp Drawings |
MS02-100B Mini ServoPress Datasheet |
AC Servo Presses Brochure |
MS02-100 Drawings |
MS02-100 stp Drawings |
- maximum Force Range, 50kN (5 Ton)
- Stroke ranges available – 100mm, 200mm and 350mm
- Maximum actuator speed of 250 mm/sec.
- Cyclic loading up to 45kN without damage
- Special Stroke Range of 500mm
Max Force | 50 kN |
Max Speed | 250 mm/s |
Stroke | 100 mm, 200 mm, 350 mm, 400 mm, 500 mm |
Interface | Digital I/O, ProfiNet, DeviceNet, EthernetIP, CC-Link |
- Force range of 5 kN (1/2 Ton)
- Stroke ranges available up to 200 mm
- Maximum speeds of up to 300 mm/s
- PC independent Force vs. Displacement Signature
- Analysis using: Limits, Envelopes & Windows
- All popular PLC Interfaces: EthernetIP, Digital I/O, DeviceNet, Profibus & CC-Link
- All limits, data and program info can be read and written through the PLC
Max Force | 5 kN |
Max Speed | 300 mm/s |
Stroke | 100 mm, 150 mm, 250 mm |
Interface | Digital I/O, Profibus, DeviceNet, EthernetIP, CC-Link |
- Force range of 20 kN, (2 Ton)
- Stroke ranges available up to 350 mm
- Maximum speeds of up to 270 mm/s
- PC independent Force vs. Displacement Signature
- Analysis using: Limits, Envelopes and Windows
- All popular PLC Interfaces: EthernetIP, Digital I/O, DeviceNet, Profibus and CC-Link
- All limits, data and program info can be read and written through the PLC
Max Force | 20 kN |
Max Speed | 270 mm/s |
Stroke | 100 mm, 200 mm, 350 mm, 400 mm |
Interface | Digital I/O, Profibus, DeviceNet, EthernetIP, CC-Link |
- Force range of 30 kN, (3 Ton)
- Stroke ranges available up to 350 mm
- Maximum speeds of up to 240 mm/s
- PC independent Force vs. Displacement Signature
- Analysis using:
- o Limits
- o Envelopes
- o Windows
Max Force | 30 kN |
Max Speed | 240 mm/s |
Stroke | 100 mm, 200 mm, 350 mm |
Interface | Digital I/O, Profibus, DeviceNet, EthernetIP, CC-Link |