BUSDAQflex, CANSASflex Base Unit
- Autonomous operation without PC supported, self-start (timer, absolute time)
- Integrated real-time signal analysis, open and closed loop control with imc Online FAMOS
- Provides 2 to 12 CAN/CAN FD nodes depending on selected housing size
- Handles a variety of protocols such as CCP, XCP, KWP2000, OBD-2, UDS, DiagOnCAN, ...
- Wide operating temperature range from -40 °C to +85 °C
- Trigger, real-time data processing, internal data storage
- GPS position detection
- Autonomous operation with self-start capability (wake-up on CAN)
The imc BUSDAQflex is a series of data loggers for CAN, CAN FD, LIN, ARINC, FlexRay, XCPoE, MVB and
EtherCAT. The basic standard configuration of 2 CAN nodes can be expanded to up to 12 nodes in the
larger device models for various field buses and vehicle buses. Along with recording of raw data streams
and log channels, live decoding of individual channels is provided and complex protocols are supported,
such as CCP, KWP2000, XCP, OBD2, UDS, DiagOnCan, TP2.0, GMLAN
The BUSDAQflex devices work Autarkic and autonomously (without PC) and are rated for operation in
extended temperature range (-40 to +85°C), making them ideal for mobile applications. The BUSDAQflex
series has very low power consumption and thanks to built-in UPS (uninterruptible power supply)
ensures complete data integrity even in case of power failure outages. As a CAN or LIN-bus logger,
imc BUSDAQflex supports a signal or bus traffic controlled Sleep-mode (Wake-on-CAN) with a start-up
time of only 200 ms and is thus perfectly suited for vehicle fleet testing.
Recorded data is stored in the device on a removable storage media (in particular Flash) and can
already be live pre-processed, analyzed and evaluated by means of an on board processing platform
(imc Online FAMOS) - which even holds for autonomous stand alone operation. This allows e.g. threshold
monitoring, min./max. values, digital filters, spectral analysis, order tracking, classification, and more.
imc BUSDAQ records measurement data and status information of any type of bus subscribers, such as
ECUs, sensors and CAN-based measurement amplifiers (e.g. imc CANSAS). In particular, modules of the
imc CANSASflex series (CANFX) can be directly docked, creating a very compact measurement system.
The tool-free click mechanism connects a data logger and digitizing measurement modules both
mechanically and electrically and requires no additional connecting cables.
imc BUSDAQ, like all imc measurement systems, is operated with the imc STUDIO software. The software
provides complete manual as well as automatic configuration of setup parameters, real-time
functions, triggering machines and storage modes. The measurement data display in curve windows and
comprehensive documentation via report generator are integral parts of the package.
Family | imc CANSAS |
Unit Type | Base |
Standalone | |
Input Type | Digital |
Digital Inputs | 16 |
Field Interface | CANbus |
Resolution | 16-bit |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
imc BUSDAQflex Datasheet Datasheet |
- imc CANSASflex Bridge Amplifier Module
- 8 Analog Input Channels
- Input Types include Voltage, Current, Strain Gauge (Quarter Bridge, Half Bridge)
- 16 bit resolution (with internal 24 bit processing)
- Built-in sensor supply
- Supports imc Plug & Measure TEDS (Transducer Electronic Data Sheets, IEEE 1451.4
- Parameterization of a measurement channel at the click of a mouse
- imc CANSASflex Differential Amplifier for Current, Voltage & Temperature
- 8 Analog Input Channels
- Simultaneous Sampling of All Channels
- Mechanically Robust
- Synchronizing of CANSAS Modules with CAN Logger
- Self-Start on Power-On
- Isolated Analog Input Module for Current, Voltage, & Temperature
- 8 Isolated Analog Input Channels
- 440 Hz bandwidth with max.
- Simultaneous Sampling of All Channels
- Measurement ranges and sampling rates can be set per channel
- Mechanically Robust
- 16 bit resolution (with internal 24 bit processing)
- Supports imc Plug & Measure TEDS (Transducer Electronic Data Sheets)
- imc CANSASflex Digital Input Module
- 16 Digital Input Channels
- Simultaneous Sampling of All Channels
- Self-Start on Power-On
- imc CANSAS Module for Frequency, Rotation, Position & Angle Counter Signals
- 4 Digital Input Channels
- All Channels Fully Conditioned
- Simultaneous Sampling of All Channels
- Analog Input Module for Voltage, Current & Temperature
- 16 Analog Input Channels
- Simultaneous Sampling of All Channels
- Measurement ranges and sampling rates can be set per channel
- 16 bit resolution (with internal 24 bit processing)
- Supports imc Plug & Measure TEDS (Transducer Electronic Data Sheets)
- Mechanically Robust
- Self-Start at Power-On
- imc CANSASflex Module for Voltage, Current & Temperature
- 16 Analog Input Channels
- Measurement Ranges & Sampling Rates Set per Channel
- 16 bit resolution (with internal 24 bit processing)
- Supports imc Plug & Measure TEDS
- Simultaneous Sampling of All Channels
- Mechanically Robust
- Self-Start at Power-On
- imc CANSASflex Module for Voltage, Current & Temperature
- 8 Analog Input Channels
- Measurement Ranges & Sampling Rates Set per Channel
- 16 bit resolution (with internal 24 bit processing)
- Supports imc Plug & Measure TEDS
- Simultaneous Sampling of All Channels
- Mechanically Robust
- Self-Start at Power-On
- imc CANSAS Universal Module
- 8 Input Channels
- Simultaneous Sampling of All Channels
- Measurement ranges and sampling rates can be set per channel
- 16 bit resolution (with internal 24 bit processing)
- Built-in sensor supply
- Mechanically Robust
- Supports imc Plug & Measure TEDS (Transducer Electronic Data Sheets)
- imc CANSASflex Output Module for Voltage & Current
- 8 Output Channels
- Simultaneous Sampling of All Channels
- Mechanically Robust
- Self-Start at Power-On
- imc CANSASflex Digital Output Module
- 16 Digital Output Channels
- Outputs are Independently Configurable for Each 8-bit Channel Group
- Self-Start at Power-On
- imc CANSASflex Digital Output Module
- 8 or 16 Digital Relays
- Relays are Selector Switches
- Self-Start at Power-On
- imc CANSAS PWM Output Module
- 8 Digital Output Channels, Isolated
- Self-Start at Power-On
- Module Configuration Exportable by Software
- imc BUSDAQ-X CAN-Datalogger
- 2-6 CAN-nodes, 8 on Request, Isolated
- 8 Digital I/O, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
Family | imc CANSAS |
Unit Type | Base , Standalone |
Digital Inputs | 4 |
Digital Outputs | 4 |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
- imc BUSDAQ-2 CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Onboard Computation & Control Logic (option)
- External Display & GPS
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | GPS, CANbus, Sync Pulse |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
- imc BUSLOG CAN-Datalogger
- 2 CAN-nodes, Isolated
- Data Storage onto Removable Drive and/or onto PC
- Overvoltage Protection
- Shock & Vibration Resistance
- Automatic Data Save upon Power Outage
Family | imc CANSAS |
Unit Type | Base , Standalone |
Field Interface | CANbus |
Communication | Ethernet |
Min Temperature | -40 °C |
Max Temperature | 85 °C |