Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

RecipSys 200, Expandable Compact Monitoring System

A compact monitoring system for reciprocating compressors delivering accurate real-time data of rider band wear, eliminating the need for periodic production shutdowns for manual inspections.
RecipSys 200
RecipSys 200
RecipSys200_1Chn
Recipsys200_2Chn
Features:
  • Phase-triggered accuracy
  • Compact monitoring system
  • Monitoring suite integration
Manufacturer:  Istec International B.V.
Quote
Brochure
Description
Specifications
Applications
Downloads
Similar Products
RecipSys 200 - Description

A compact monitoring system for reciprocating compressors delivering accurate real-time data of rider band wear, eliminating the need for periodic production shutdowns for manual inspections.

RecipSys 200 - Specifications
Input Type±20 V DC
Output Type0 - 10 V DC
0 - 20 mA
4 - 20 mA
Excitation24 V DC
IsolationYes
RecipSys 200 - Applications

The system architecture is designed for a wide variety of applications. A single module provides a reliable and cost-effective solution for overspeed monitoring. Redundancy and voting structures can be created for applications with higher requirements and to increase availability. Typical applications include:

  • Microturbines
  • Wind turbines
  • Compressors and pumps
  • Aeroderivative gas turbines
  • Gas and steam turbines
  • Marine applications
RecipSys 200 - Downloads
RecipSys 200 - Similar Products
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • Measures Voltage ranges: ±0.2V, ±2V, ±20V, ±200V, ±300V, and ±600V.
  • Measures Current ranges: ±2 mA, ±20 mA, ±200 mA, and ±5A.
  • High resolution (0.0015% of span) and accuracy (±0.02% of span).
  • Input ranges are user-selectable and factory-calibrated.
  • 5V, 10V, or 24V dc transducer excitation output, isolated.
Interface
RS-232,
RS-485
Input Type
±0.2V DC,
±2 V DC,
±20 V DC,
±200 V DC,
±300V DC,
±600V DC,
±2 mA,
±20 mA,
±200 mA,
±5 A
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Excitation
5 V DC,
10 V DC,
24 V DC
Isolation
Yes
Min Temperature
-40°C
  • Process Monitor, for process signals
  • Extremely fast digital transducer
  • Isolated Versions Available
  • USB Connectivity for easy calibration
  • DAQ Mode with a measuring rate - up to 7500 measurements per second
  • 2 Button teach-in for Potentiometer
  • Teach-in, allows easy setting of both min. and max. of the measuring range
  • Output: 4…20 mA/0…10 V
Interface
USB
Input Type
0 - 10 V DC,
0 - 20 mA,
4 - 20 mA
# of Inputs
1
Output Type
0 - 10 V DC,
4 - 20 mA,
RS-485
Excitation
15 V DC,
24 V DC
Isolation
Yes
  • 480 calibrated input ranges, +/- 0.02 to +/- 200 V or +/- 0.1 to +/- 100mA (unipolar/bipolar)
  • Output Signals: +/- 20 mA, +/- 10V, or 4…20 mA
  • Flexible set-up through onboard dipswitches
  • Galvanically isolated to 1000 V AC/DC (input and output channels), with test voltage of 5.4 kV AC
  • 10kHz Cut-off frequency
  • Response Time of 70 microseconds (T90)
  • Compact, 22.5 mm wide din-rail mountable housing
  • Broad-range power supply 20 … 253 V AC/DC
Input Type
0 - 10 mV DC,
0 - 50 mV DC,
0 - 100 mV DC,
0 - 1 V DC,
±5 V DC,
±10 V DC,
±20 V DC
Output Type
±10 V DC,
4 - 20 mA,
±20 mA
Max Bandwidth
10 kHz
Isolation
Yes
Supply Power
20 - 28 V DC,
80 - 250 V AC
  • Strain Gauge & Potentiometer Input Amplifier
  • 50 V Continuous Isolation
  • Accuracy: ± 0.05%
  • DIN Rail Mounted
  • In-Line Amplifier (Option)
  • Aluminum Housing
  • Protection Class: IP40
Input Type
0 - 10 mV DC,
0 - 100 mV DC,
0 - 1 V DC,
0 - 10 V DC,
±10 V DC,
Potentiometer,
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
1 kHz,
4 kHz
Excitation
2.5 V DC,
5 V DC,
10 V DC
Isolation
Yes
  • Voltage Input Module
  • 1500 V Transformer Isolation
  • True 3-Way Isolation
  • Accuracy: ± 0.03%
  • DIN Rail Mounted Module
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240 V AC Continuous
Input Type
±1 V DC,
±2 V DC,
±3 V DC,
±4 V DC,
±5 V DC,
±6 V DC,
±7 V DC,
±8 V DC,
±9 V DC,
±10 V DC
# of Inputs
1
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
3 kHz
Excitation
10 V DC
Isolation
Yes