Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

KS823B, High Sensitivity Tri-axial Accelerometer

Triaxial accelerometers for simultaneous measurement of vibration in three perpendicular axes, that are designed for the measurement of building vibration to DIN 4150, wind turbines and other sensitive applications at large structures.
KS823B
KS823B
KS823B-2.png
KS823B.png
KS823B-5.png
KS823B-6.png
KS823B-7.png
Features:
  • Sensitivity: 500mV/g
  • Measuring range: ±12 g
  • Linear frequency range: 0.07 .. 6000 Hz, (±3 dB)
  • Protection grade: IP67
  • Connector: Radial Binder 718
  • Weight: 365 g
Manufacturer:  MMF
Quote
Datasheet
Specifications
Applications
Models & Accessories
Downloads
Related Products
KS823B - Specifications
TypeVoltage Mode (IEPE)
# of Axis3
Full Scale10 g
Output500 mV/g
MaterialStainless Steel
Connection4-Pin Radial Connector
Min Temperature-40 °C
Max Temperature120 °C
KS823B - Applications

Building, Tower, Bridge low Frequency and low amplitude Sway and Vibration.

KS823B - Models & Accessories
Accessories
034-B711f-BNC:Adapter cable from Binder 711 to 3 BNC plugs, 0.5 m
088-B718G-B711-5IEPE cable for triaxial accelerometers with Binder 718 and Binder 711 connectors
508Rare-earth magnetic base for flat and curved surfaces, M8 (fem.)
529Wall and ceiling adapter for KS823B, without screw ring
629Wall and ceiling adapter for KS823B, with screw ring
729Tripod floor plate for accelerometers
M208A8-channel IEPE conditioner
M33IEPE amplifier module
M72A3Charge Amplifier / IEPE Amplifier
KS823B - Downloads
KS823B - Related Products
  • Binder 711 female Connector on Sensor end
  • BNC connector on Instrument end
  • Temp. Range is -20 to 80 °C
  • Cable Ø - 2,7 mm
  • Quick delivery on quantity of 1 to 10.
This cable is for IEPE, can be provided in lengths from 3 ft. (1 m) up to 15 ft. (5 m).
  • Binder 718 female Connector on Sensor end
  • Binder 711 male connector on Instrument end
  • Temp. Range is -20 to 80 °C
  • Cable Ø - 5 mm
  • Quick delivery on quantity of 1 to 10.
This cable is for IEPE, can be provided in lengths of 15 ft. (5 m).
  • Measurement and display of RMS and peak values.
  • Wide frequency range (Bandwidth) from 0.1 Hz to 100 kHz
  • Incremental gain of 0.1 to 1000 for input / transducer sensitivity.
  • Vibration monitoring with relay outputs.
  • Relay output with adjustable trip levels
  • Remote measurement via Ethernet interface and web browser.
  • TEDS support IEEE 1451.4 with automatic transducer sensitivity normalization
  • Bench top or 19" rack mounting enclosure
Input Type
Piezoelectric (IEPE)
# of Inputs
8
Output Type
±10 V DC
Max Bandwidth
100 kHz
Supply Power
10 - 28 VDC
Min Temperature
-10°C
  • Gains of 1, 10, 100 & 1000
  • Low pass filter modules: (FB2); 0.1 .. 30 kHz, optional
  • High pass filter modules: (FB3); 3 .. 1000 Hz; optional
  • BNC Input & Output Connectors
  • Powered from 5 .. 28 VDC, modules join together
Input Type
0 - 10 V AC,
IEPE
# of Inputs
1
Output Type
±10 V DC
Bandwidth
20 kHz
Supply Power
5 V DC,
10 - 30 V DC
  • Gain Selections: 0,1 / 1 / 10 / 100 / 1000 mV/pC; 0 / 20 / 40 / 60 dB
  • Single and Double Integrators
  • Low pass filters: 0.1 / 1 / 10 / 50 kHz
  • High pass filters: 0.1 / 3 Hz
  • 4 digit mV or pC LED display(s)
  • Input & Output BNC connectors
  • USB interface on M72S8, Rack Case
  • Power Supply: 7-30Vdc, 115 Vac Adaptor
Input Type
0 - 10 V AC,
Piezoelectric (IEPE)
# of Inputs
1,
3
Output Type
±10 V DC
Max Bandwidth
50 kHz
Supply Power
9 V DC (Battery),
24 - 30 V DC,
115 V AC
Min Temperature
-10°C
  • Comparison with limiting values to DIN 4150-3
  • Simple generation of reports
  • Detection of the main frequency
  • Recording of vibration events and real-time signals
  • Available as kit: VM-STRUC Kit with accelerometer KS823B
The latest version of VibroMetra software can measurement and evaluation of vibrations in buildings to DIN 4150-3 for the determination of their effects on structures. Recording of vibration events and real-time signals.
  • Graphical trend display
  • Main frequency display
  • Electronic identification of measurement points with VMID points via the sensor base
  • USB interface, PC software for measuring point management to MIMOSA convention and measuring data archiving
  • Vibration Velocity; 0.1 - 1000 mm/s; 2 - 100 Hz; 2 - 1000 Hz; 10 - 1000 Hz
  • Vibration displacement; 0.01 - 60 mm; 3 - 60 Hz; 2 - 300 Hz; 3 - 200 Hz; 2 - 1000 Hz; 10 - 1000 Hz
Enhanced Vibration Measurements, Signal Processing & Numerical / Graphical Display for Quality Control and Industrial Process Monitoring. The display is a Brilliant, power-saving colored OLED.
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us
© A-Tech Instruments Ltd.