SCMPB04, Analog I/O Back Panel
![SCMPB04, Analog I/O Back Panel](img/series/SCMPB04_9eb06f66.png)
![SCMPB04, Analog I/O Back Panel](img/series/SCMPB04_9eb06f66.png)
![SCMPB04-Dual Module Backplane Dimensions](img/series/SCMPB04-Dual_Module_Backplane_Dimensions.png)
![SCMPB 5B Backplane DIN Rail Mount Option](img/series/SCMPB_5B_Backplane_DIN_Rail_Mount_Option_484e5637.jpg)
![SCM5B General Electrical Connections](img/series/SCM5B_General_Electrical_Connections_56d51b41.png)
Family | Dataforth 5B |
Input Type | 0 - 10 mV DC |
0 - 5 V DC | |
0 - 10 V DC | |
0 - 50 V DC | |
±10 V DC | |
±40 V DC | |
0 - 10 V AC | |
4 - 20 mA | |
Strain Gauge | |
Frequency | |
Thermocouple | |
RTD |
SCMPB04 | SCMPB04 Dual channel back panel. No mounting hardware included |
SCMPB04-1 | Dual channel backpanel without cold junction compensation circuits. Use when cost savings is desired and thermocouple input modules SCM5B37 and SCMPB47 will not be used. No mounting hardware included. |
SCMPB04-2 | Dual channel backpanel with DIN rail mounting hardware. Shipped fully assembled. |
SCMPB04-3 | Dual channel backpanel without cold junction compensation circuits and with DIN rail mounting hardware. Shipped fully assembled. |
SCM5B Backplanes and Accessories Datasheet |
- Narrow Bandwidth Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | ±10 mV DC, ±50 mV DC, ±100 mV DC, ±1 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 0 - 10 V DC, ±5 V DC, ±10 V DC |
Bandwidth | 4 Hz |
Isolation | Yes |
- Narrow Bandwidth Voltage Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | ±1 V DC, ±5 V DC, ±10 V DC, ±20 V DC, ±40 V DC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 0 - 10 V DC, ±5 V DC, ±10 V DC |
Bandwidth | 4 Hz |
Isolation | Yes |
- True RMS Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 480 V AC & DC Max
Family | Dataforth 5B |
Input Type | 0 - 100 mV AC, 0 - 1 V AC, 0 - 10 V AC, 0 - 150 V AC, 0 - 300 V AC, 0 - 1 A AC, 0 - 5 A AC |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 0 - 10 V DC, 0 - 1 mA, 0 - 20 mA, 4 - 20 mA |
Isolation | Yes |
Supply Power | 5 V DC |
- Linearized 2- or 3-Wire RTD Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.06°C to ± 0.36°C
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | RTD |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 0 - 10 V DC |
Bandwidth | 4 Hz |
Isolation | Yes |
- Non-Linearized Thermocouple Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | Thermocouple |
# of Inputs | 1 |
Output Type | 0 - 5 V DC, 0 - 10 V DC |
Bandwidth | 4 Hz |
Isolation | Yes |
- Strain Gauge Input Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC |
Bandwidth | 10 kHz |
Excitation | 3.33 V DC, 10 V DC |
- Analog Output Module
- 1500 V Transformer Isolation
- Accuracy: ± 0.03%
- Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Family | Dataforth 5B |
Input Type | 0 - 5 V DC, ±5 V DC, ±10 V DC, 0 - 20 mA |
# of Inputs | 1 |
Output Type | 0 - 20 mA, 4 - 20 mA, ±20 mA |
Bandwidth | 275 Hz, 400 Hz |
Isolation | Yes |
Family | Dataforth 5B, Dataforth 7B |
Input Type | 0 - 10 mV DC, 0 - 40 V DC, ±10 V DC, 0 - 10 V AC, 4 - 20 mA, Strain Gauge, Frequency |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
Isolation | Yes |