ForTest - T8970, Universal Continuous Measurement leak Tester
- Continuous measurement
- Designed for the gas sector
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
The ForTest T8970, is a particular leak testing equipment with continuous measurement, designed for specific parts with gas ramps, stoves or repair stations. With standard flow valves, it's ideal for continuous testing volumes up to 8 liters for the Gas sector.
Low maintenance, stable and noise free. It has double Faraday optical-isolated cage, which reduces the settling times under 18 ms. This technology will ensure very fast testing in sequence of the various rings and taps of a gas ramp, starting in automatic mode as soon as you connect to the inbound gas supply, and displaying the leaks detected in real time.
Assembly of the latest generation solenoid valves has enabled a 30% increase in the filling speed compared to the previous model, maintaining reliability unaltered over time.
The T8970 has an automatic electronic regulator, which enables stable and continuous adjustment of the test pressure, especially in the tap opening phase.
Limitless connectivity.
The new T8970 equipment includes ports for the USB slave, RS232, RS485, Can bus and TTY. Assembly may also include an optional Ethernet port and a 26-pole connector with 4 inputs and 8 outputs, which are completely programmable, for interfacing with the external valves, safety barriers, switches, etc...
The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade the firmware.
The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.
Always better measurements.
The test cycle was further accelerated thanks to processor and coprocessor interaction, maintaining the reliability that has always made ForTest unique.
We can say with certainty that the T8970 prevails as one of the most advanced measurement systems in the world, thanks to the centering technology in windows and the double Faraday optical-isolated cage, which reduces the settling times under 18 ms.
This gives a real measurement resolution of 0.1 Pa at 1 bar (0.5 Pa at 6 bar), stable and noise-free.
Optimized pneumatic section.
Assembly of the latest generation solenoid valves has enabled a 30% increase in the filling speed compared to the previous model, maintaining reliability unaltered over time.
This instrument does not require expensive maintenance in the pneumatic department. Actually, fortest's objective is to make them increasingly reliable and long-lasting.
Innovative design.
What appears to be a simple design, in fact hides an in-depth study to make use and understanding of the equipment as simple as possible.
The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T8970 suitable for use in the laboratory and on the production line.
The extensive internal menus are easy to understand and the graphic interface was designed to only display important information.
Everything is exactly where it should be.
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232 |
RS-485 | |
Profinet | |
EtherCAT | |
Ethernet TCP/IP | |
Accuracy | 0.5% |
Aerospace, Automotive, Household Appliances, Electronics, Refrigeration, Packaging and many more
External exhaust solenoid with protection filter | |
External start button | |
External start/abort pushbutton | |
External pushbutton 4 programs selection | |
Start pedal | |
Barcode reader | |
Adhesive label for printer 4500pcs | |
Aux signals extension cable | |
Air filter | |
Staubli male connector | |
Precision micrometer nozzle | |
Micrometer nozzle | |
M series manager software | |
TTY | |
Serial protocol | |
PC serial cable owner ---> M Series | |
External temperature probe | |
MIXER-07 | |
Software Data Manager | |
Staubli female fitting | |
Thermal printer with peel-off | |
Thermal printer without peel | |
Adapter cable AUX M Series ---> ET Series | |
Remote Start / Abort / Good / Reject | |
Air filter 5 micron | |
Frontal connector for Staubli calibrated leak | |
Frontal precision pressure regulator | |
Electronic pressure Regulator | |
Auto zero primary pressure circuit | |
Pre-Filling | |
Secondary Output of Waste (third result) | |
Leak Analog Output | |
I/O 24 Vdc expansion signal card | |
Ethernet plug/TCP-IP | |
Active USB port | |
WI-FI connection | |
Radio remote control selection Kit | |
High resolution measure - (STANDARD) | |
Capacitance meter for piece volume measure - (STANDARD) |
T8970 Universal Continuous Measurement leak Tester Datasheet |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 3.5" Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485 |
- Two channel equipment
- 3 types of pressure adjustment
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Faster parameter programming
- Multiple Languages, English, French, Spanish, Italian, …
- Barcode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus )
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- 2.5 “ high-resolution Oled display
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
- Password Protection
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232 |
- Black anodized aluminium case
- 3mm. plexiglass front panel
- Dimensions: L 90 mm, H 150 mm, P 70 mm
- Weight 450gr
- Measure resolution of pressure decay of 0.1 Pa (for equipment until 1 bar)
- ForTest, Modbus or Canbus protocol
- USB port for PC connection
- Serial port for connection with printer or bar code reader
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
- Two different testing methods
- USB Type-B female connector for PC
- 6 languages (English, Italian, French, German, Spanish, Portuguese)
- Mechanical Start/Stop button
- Firmware update via USB stick
- Password protection
- 24V I/O (Start,Stop,Test,Good,Reject,4BCD)
- available measurement units: mbar, bar, psi, mmHg, mmH20, Pa, HPa, cc/min, cc/h, pressure/s , l/h , l/min
Type | Flow, Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EtherCAT, Ethernet TCP/IP |
- Extremely low leak detection
- 2 Independent measurement sections
- Test pressure up to 100bars
- Colour display
- Password protection
- I/O Signals (Start, Stop, Filling, Test, Good, Reject, 4BCD)
- Mechanical Start/Stop button
- Unit measurement available mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s.
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485 |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Faster parameter programming
- Multiple Languages, English, French, Spanish, Italian, …
- Barcode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus )
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Multiple Languages, English, French, Spanish, Italian, …
- BarCode Reader inputs and Printer output
- Sequence – Pre-Fill to Balance Pressure, Reduced to Balanced Test Pressure, Stabilize, Measure Differential Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 3.5" Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485 |