ForTest - T4890, Absolute Micro-Channel Bi-Channel Test Instrument
- Black anodized aluminium case
- 3mm. plexiglass front panel
- Dimensions: L 90 mm, H 150 mm, P 70 mm
- Weight 450gr
- Measure resolution of pressure decay of 0.1 Pa (for equipment until 1 bar)
- ForTest, Modbus or Canbus protocol
- USB port for PC connection
- Serial port for connection with printer or bar code reader
- Oled high contrast display 2.5” 128x64 pixel
- Frontal leds indicating Test running, Good, Reject
- Inputs of Start, Abort, recall up to 7 programs
- Outputs for Test running, Good, Reject, Discharge
- Possibility to store 50 programs for each channel
- Fastening to Din bar, panel or directly on the station
- External Pressure and flow regulators (on demand)
- Pressure full scale: (mbar) : -1000, 200, 500, 1000, 2000, 6000
- Power supply: 24 Vdc
- Different pneumatics available for tubes (mm): 4x2.7, 6x4, 8x6
- Test Gas: Hydrogen, Compressed air, Nitrogen
The ForTest T4890 is the new and revolutionary double channel leak tester at absolute decay by ForTest. Born to be integrated on benches with high production rates, it provides a hardware that can be compared to that of top series equipment, and with a measurement resolution up to 0,1 Pa.
The T4890 provides an innovative 2.5 “ high-resolution Oled display, a USB port for direct connection with PC management software available and several expansion ports to external automations, indicator lights, limit switch, programming keyboards, etc…
The black anodized aluminium case has been designed for fixing it to a Din bar, or to a panel, or by pneumatic connectors, directly on the station in order to minimize the volume under testing.
Thanks to its double pneumatics, ultra fast internal valves and small testing connectors, testing time is reduced by half compared to single-channel equipment.
Following a philosophy of fast assembly and quick start, the T4890 has been designed to replace “do it yourself” testing stations composed by pressure transducers, pneumatic groups and PLCs, allowing “plug and play” applications without programming and installation costs. Just few minutes after assembling, you will be fully operational.
The T4890 can communicate via protocol with equipment that is of ForTest, Canbus or Modbus. Working scales go from -1 to 6 bar.
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
For testing gas, compressed air, and Nitrogen
External exhaust solenoid with protection filter | |
External start button | |
Start pedal | |
Barcode reader | |
Adhesive label for printer 4500pcs | |
Aux signals extension cable | |
Air filter | |
M series manager software | |
Serial protocol | |
External 24 VDC power supply | |
Software Data Manager | |
Thermal printer with peel-off | |
Thermal printer without peel | |
Remote Start / Abort / Good / Reject | |
Air filter 5 micron |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 3.5" Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485 |
- Two channel equipment
- 3 types of pressure adjustment
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Continuous measurement
- Designed for the gas sector
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EtherCAT, Ethernet TCP/IP |
- 2.5 “ high-resolution Oled display
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
- Password Protection
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232 |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Faster parameter programming
- Multiple Languages, English, French, Spanish, Italian, …
- Barcode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus )
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Two channel equipment
- 3 types of pressure adjustment
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Multiple Languages, English, French, Spanish, Italian, …
- BarCode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus)
- Dimensions 270 x 160 x 300 mm
- Weight 8 Kg
Type | Pressure Decay |
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.5 in Color Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Ideal for little volume applications and that can admit very low leakages and very high speed test.
- 2,5 “ high-resolution Oled display
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232 |
- 2.5 “ high-resolution Oled display
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
- Password Protection
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232 |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, EthernetIP |