ForTest - T8980, "Compliance" Universal Leak tester
- Extremely low leak detection
- 2 Independent measurement sections
- Test pressure up to 100bars
- Colour display
- Password protection
- I/O Signals (Start, Stop, Filling, Test, Good, Reject, 4BCD)
- Mechanical Start/Stop button
- Unit measurement available mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s.
The ForTest T8980 equipment has 2 measurement sections, the first injects test air inside the piece being tested, the second measures the pressure increase inside the gaps in the containment bell. Then, if the piece being tested has a leak, it will transfer the pressure load in the bell, causing the pressure to increase inside it, which will then be detected by the leaks measurement section.
By doing so, in complete safety, very high test pressure is used (even 100 bar) and extremely low leaks are detected, even a few cc/h.
Limitless connectivity.
The new T8980 equipment includes ports for the USB slave, RS232, RS485, Can bus and TTY. Assembly may also include an optional Ethernet port and a 26-pole connector with 4 inputs and 8 outputs, which are completely programmable, for interfacing with the external valves, safety barriers, switches, etc...
The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware.
The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.
Always better measurements.
By nature, compliance technology enables a measurement sensitivity even better than absolute decay, guaranteeing a decay resolution of 0.1 Pa up to 6 bar testing.
The implementation of new pressure sensors, combined with the measurement section with centering technology in windows and double Faraday optical-isolated cage has made further improvement possible of the tool performance.
Optimized pneumatic section.
Assembly of the latest generation solenoid valves has enabled a 30% increase in the filling speed compared to the previous model, maintaining reliability unaltered over time.
Fortest's equipment does not require expensive maintenance in the pneumatic department. Actually, their objective is to make them increasingly reliable and long-lasting.
Innovative design.
What appears to be a simple design, in fact hides an in-depth study to make use and understanding of the tool as simple as possible.
The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T8980 suitable for use in the laboratory and on the production line.
The extensive internal menus are easy to understand and the graphic interface was designed to only display important information.
Everything is exactly where it should be.
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232 |
RS-485 | |
Accuracy | 0.5% |
Medical, Automotive, Household Appliances, Gas, Packaging and many more
External exhaust solenoid with protection filter | |
External start/abort pushbutton | |
External pushbutton 4 programs selection | |
Start pedal | |
Barcode reader | |
Adhesive label for printer 4500pcs | |
Aux signals extension cable | |
Venturi Vacuum generator | |
Air filter | |
Staubli male connector | |
Precision micrometer nozzle | |
Micrometer nozzle | |
M series manager software | |
TTY | |
Serial protocol | |
PC serial cable owner ---> M Series | |
External temperature probe | |
MIXER-07 | |
Software Data Manager | |
Staubli female fitting | |
Thermal printer with peel-off | |
Adapter cable AUX M Series ---> ET Series | |
Software "Data Manager" | |
Air filter 5 micron | |
Interior exhaust valve | |
Frontal precision pressure regulator | |
Pneumatic module of remote measurements | |
Electronic pressure Regulator | |
Auto zero primary pressure circuit | |
Pre-Filling | |
Waiting Primary pressure reading - (STANDARD) | |
Secondary Output of Waste (third result) | |
Leak Analog Output | |
I/O 24 Vdc expansion signal card | |
Bi-manual logic Start Input | |
Ethernet plug/TCP-IP | |
Active USB port | |
WI-FI connection | |
Radio remote control selection Kit | |
High resolution measure - (STANDARD) | |
Capacitance meter for piece volume measure | |
Double branches of pre-regulated pressures | |
Indirect measure - (STANDARD) |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Multiple Languages, English, French, Spanish, Italian, …
- BarCode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus)
- Dimensions 270 x 160 x 300 mm
- Weight 8 Kg
Type | Pressure Decay |
# of Channels | 2 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.5 in Color Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Multiple Languages, English, French, Spanish, Italian, …
- BarCode Reader inputs and Printer output
- Sequence – Pre-Fill to Balance Pressure, Reduced to Balanced Test Pressure, Stabilize, Measure Differential Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Resolution from 1 Pa
- Colour display
- USB pen drive for storing results and test parameters
- Bluetooth Low Energy and WiFi interfaces on-board
- 99 Test Programs
- USB Type-B female connector for PC
- 6 Languages (English, Italian, French, German, Spanish, Portuguese)
- Mechanical Start/Stop button
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, EthernetIP |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232, RS-485, EthernetIP |
- Ideal for little volume applications and that can admit very low leakages and very high speed test.
- 2,5 “ high-resolution Oled display
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | Numeric |
Data Storage | USB |
Interface | RS-232 |
- Two different testing methods
- USB Type-B female connector for PC
- 6 languages (English, Italian, French, German, Spanish, Portuguese)
- Mechanical Start/Stop button
- Firmware update via USB stick
- Password protection
- 24V I/O (Start,Stop,Test,Good,Reject,4BCD)
- available measurement units: mbar, bar, psi, mmHg, mmH20, Pa, HPa, cc/min, cc/h, pressure/s , l/h , l/min
Type | Mass Flow, Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EtherCAT, Ethernet TCP/IP |
- Continuous measurement
- Designed for the gas sector
- Multiple Programs for different parts
- HMI touchscreen controller
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 1 Pa (0.00015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EtherCAT, Ethernet TCP/IP |
- Manual Pressure Regulation
- Multiple Programs for different parts
- Multiple Languages, English, French, Spanish, Italian, …
- Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 3.5" Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485 |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Faster parameter programming
- Multiple Languages, English, French, Spanish, Italian, …
- Barcode Reader inputs and Printer output
- Sequence – Pre-Fill Pressure, Reduced to Test Pressure, Stabilize, Measure Absolute Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus )
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |
- Electronically Controlled Pressure Regulation
- Multiple Programs for different parts, with the possibility of different pressures
- Multiple Languages, English, French, Spanish, Italian, …
- BarCode Reader inputs and Printer output
- Sequence – Pre-Fill to Balance Pressure, Reduced to Balanced Test Pressure, Stabilize, Measure Differential Pressure Decay
- Data Collection by Serial Number, using a PC or PLC ( optional Field buses, Ethernet IP, ProfiNet, EtherCAT Modbus)
Type | Pressure Decay |
# of Channels | 1 |
Resolution | 0.1 Pa (0.000015 psi) |
Display | 6.2 in Colour Display |
Data Storage | USB |
Interface | RS-232, RS-485, Profinet, EthernetIP, EtherCAT, Ethernet TCP/IP |