4506, Precision Pt 100 Simulators
- 24 set temperature values
- Calibration per DIN EN 60751
- Resistor material: ZERANIN®
- Temperature coefficient ≤ 2 ppm/K
- Pt 100, Pt 500, Pt 1000
The unit houses a high-quality switch with precision wire-wound resistors made of ZERANIN®. It is installed in a handy and rugged metal casing (with DIN sockets). 24 set temperature values are simulated using the selector switch in accordance with DIN EN 6075 standard values for resistance thermometers (Pt 100).
The simulated resistance value, corresponding in its value to the individually set temperature, is picked up at the “RSim”output socket. The four-wire connecting system permits
the connection of a separate current and voltage path. Supply lead resistance is therefore eliminated and does not appear in the measurements.
The 24 temperatures are chosen to provide several calibration points suitable for most measuring instruments. The resistors are subject to careful artificial ageing before trimming.
This special process and trimming about half the tolerance guarantee a long-term stability of < 0.01 % for years. The material used for the resistors, ZERANIN®, has a temperature coefficient of less than 2 ppm/K. Allowances for ambient temperatures are therefore superfluous.
Output Type | RTD |
The precision Pt 100 simulator is used wherever measuring instruments or controlling systems have to be tested or calibrated with great precision.
The standard design, model 4506, simulates 24 set temperature values. Totally different temperature ranges are required in the case of special applications, such as in the food industry, the medical science etc. Model 4506 S is recommended for these applications and can be fitted with 24 temperature values according to customer specifications.
A distinctive feature of these simulators is their easy operation. The resistance values required for simulation are directly set in °C. There is no need to use loof-up tables. In cases a certificate is being demanded more than ever for measurements. It is available under order code 45DKD
4506 | |
4506S |
4506 Series Overview Datasheet |
- Simulation range -100 °C up to +500 °C
- Resolution 0.1 °C
- Calibration in accordance to DIN EN 60751
- Simulation of line resistance 10 Ohms, 20 Ohms or 30 Ohms
- Compact, easy to handle aluminium-housing
Output Type | RTD |
- Range: -200°C ...+850°C (Accuracy: 0.02°C)
- Simulation of Pt100, Pt200,Pt500, Pt1000, Ni100 & Ni1000 Sensors
- Temperature scales: ITS 90 & IPTS 68
- Manual or remote control via RS232/IEEE488
- A sturdy aluminium housing
Output Type | RTD |
- Wide Range of Inputs and Outputs all in one Digistant
- Simulate and Measure
- Vdc: 1mV up to 20V
- Current: 1mA up to 24mA
- Resistance: 5Ω up to 4000Ω & HART: 250Ω
- Frequency/Pulse: 2 CPM up to 10KHz
- RTD: Pt100 l 1000, Ni
- TC: J, K, T, E, R, S, B, C
Input Type | DC Voltage, DC Current, Thermocouple, RTD |
Output Type | DC Voltage, DC Current, Thermocouple, RTD |
Interface | USB |
Supply | Battery, 230 V AC |
- More than 60 fixed temperature values from - 200 C... + 850 C are in stock
- Calibration in acc. with DIN EN 60751
- +/- 0.02% tolerance for the models 1144-Pt 100, 1144-Pt 500 and 1144-Pt 1000
- +/- 0.05% tolerance from the resistance value in the range - 200 C...- 50 C the model 1146-Pt 100
Output Type | RTD |
- DC voltage up to ±100.0000 V, ±0.002 %
- DC current up to ±50.0000 mA, ±0.005 %
- Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2
- 32 Automatic sequence functions ( ramp function, max. of 100 steps )
- can be operated both via the keypad or via the Ethernet & USB interfaces
- RTD Simulation Pt100 ... Pt1000, Ni100 ... Ni1000 (optional)
- True ohmic resistance simulation 10 Ω ... 300 kΩ (optional)
- Frequency simulation 0.01 Hz ... 15 kHz (optional)
Input Type | DC Voltage, DC Current, Thermocouple, RTD |
Output Type | DC Voltage, DC Current, Thermocouple, RTD |
Interface | USB, Ethernet TCP/IP |