T600, Speed and Direction Controller - DISCONTINUED
- High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 mA
- 2 frequency + 1 analog + 2 binary inputs
- Direction and creep detection
- Temperature measurement with PT100
- 2 current, 4 relay and 2 Open Collector outputs
- Sensor monitoring for all sensor technologies
- Ethernet interface - confi guration via Windows software
- Extensive parameter and limit setting possibilities
- Programmable logical, diagnostic and measurement functions
- Plug in terminals
T600’s allow you the freedom to choose the functions or system configuration that best match your application. As well as being replacements for previous generation tachometers they can process multiple sensors data including frequency, 0/4…20mA analog, a directly connected PT100 temperature resistor, binary inputs & sensors with CAN interface. T600 takes T500 to a higher level. The 2 frequency inputs may either be interpreted as speed data or speed and timing signal. Logic analyses and mathematic calculations expand the possibilities.
Want to know when a trip occurred? Could you use more gear teeth than space allows? Need to swap between different parameter sets? - No problem - the T600 MultiTasker provides the solution. Uniquely, the T600’s also enable you to logically combine decision parameters from more than one sensor or command to create control signals.
Interface | TCP/IP |
Input Type | 0 - 20 mA |
4 - 20 mA | |
Frequency | |
RTD | |
CANbus | |
# of Inputs | 3 |
Output Type | 0 - 20 mA |
4 - 20 mA | |
Isolation | Yes |
Supply Power | 18 - 36 V DC |
90 - 264 V AC |
T600 | |
T601 |
T600 Speed and Direction Datasheet |
- Accepts 1 signal input from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Two configurable relays (10 ms response time) for multiple speed functions
- One highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- One Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 1 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Four configurable high speed relays (10 ms response time) for multiple speed functions
- Two highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Two Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 2 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Six configurable high speed relays (10 ms response time) for multiple speed functions
- Three highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Three Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 3 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 5 kHz |
Excitation | 24 V DC |
- Overspeed, Underspeed and Acceleration Detection
- Designed for versatility and scalable to the application
- Suitable for API 670 and API 612 applications
- Certified SIL 2 capability
- Fast 8 ms system response time
- 2 safety relays + 1 safety analog output per module
- Suitable for all common sensor types
Interface | TCP/IP |
Input Type | ±100 mV DC, ±80 V DC, Frequency |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
Max Bandwidth | 10 kHz |
Excitation | 20 V DC |
- High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 mA
- 2 frequency + 2 binary inputs
- 2 current, 4 relay and 2 Open Collector outputs
- Sensor monitoring for all sensor technologies
- Ethernet interface - confi guration via Windows® software
- Extensive parameter and limit setting possibilities
- Programmable logical, diagnostic and measurement functions
- Supply 18..36 VDC or 90..264 VAC
Interface | TCP/IP |
Input Type | Frequency |
# of Inputs | 2 |
Output Type | 0 - 20 mA, 4 - 20 mA |
Isolation | Yes |
Supply Power | 18 - 36 V DC, 90 - 264 V AC |
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Six configurable high speed relays (10 ms response time) for multiple speed functions
- Three highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Three Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 3 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 5 kHz |
Excitation | 24 V DC |