Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

MSX-ilog-RTD, Ethernet Data Logger for Temperature Measurements

The MSX-ilog-RTD/TC data logger features 8 or 16 differential inputs for thermocouples or RTDs. The parametering and visualization of the measured values are carried out via an integrated website.
MSX-ilog-RTD, Ethernet Data Logger for Temperature Measurements
MSX-ilog-RTD, Ethernet Data Logger for Temperature Measurements
Features:
  • 16/8 Differential Inputs
  • Thermocouple/RTD/Pt100/Pt1000
  • Acquisition, Visualization & Analysis
  • No Software Installation Needed
  • Automatic Storage of Measured Values
  • 4 GB Built-in Flash Memory
  • Robust Metal Housing
Manufacturer:  ADDI-DATA GmbH
Quote
Datasheet
Specifications
Models & Accessories
Downloads
Similar Products
MSX-ilog-RTD - Specifications
FamilyADDI-DATA MSX
Unit TypeStandalone
Input TypeThermocouple/RTD
Analog Inputs8
16
Resolution24-bit
CommunicationEthernet
Min Temperature-25 °C
Max Temperature85 °C
IP RatingIP65
MSX-ilog-RTD - Models & Accessories
Models
MSX-ilog-RTD-1616 RTD Inputs, 24-bit Resolution
MSX-ilog-RTD-88 RTD Inputs, 24-bit Resolution
MSX-ilog-TC-1616 Thermocouple Inputs, 24-bit Resolution
MSX-ilog-TC-88 Thermocouple Inputs, 24-bit Resolution
MSX-ilog-RTD - Downloads
MSX-ilog-RTD - Similar Products
  • 16/8/4 Differential Inputs
  • For Thermocouples or RTD
  • 24-bit Resolution
  • Simultaneous Sampling of up to 8 Channels
  • 24 V Digital Trigger Input
  • 64 MB Onboard SDRAM for Data Storage
  • Robust Metal Housing
Family
ADDI-DATA MSX
Unit Type
Standalone
Input Type
Thermocouple/RTD
Analog Inputs
4,
8,
16
Field Interface
Sync Pulse
Resolution
24-bit
  • 8 Analog Input Channels
  • Half-Bridge, LVDT, Mahr or Knaebel Inputs
  • 1 Incremental Counter Input
  • 1 Temperature Input
  • Simultaneous Sampling of up to 8 Channels
  • Optical Isolation 1000 V
  • 24 V Digital Trigger Input
  • Robust Metal Housing
Family
ADDI-DATA MSX
Unit Type
Standalone
Input Type
Voltage,
Thermocouple/RTD,
Frequency,
Encoder
Analog Inputs
9
Digital Inputs
1
Field Interface
Sync Pulse
  • 16/8/4 Analog Input Channels
  • Half-Bridge, LVDT, Mahr or Knaebel Inputs
  • 24-bit Resolution
  • Optical Isolation 1000 V
  • Digital Output with Compare Logic, 24 V (option)
  • 24 V Digital Trigger Input
Family
ADDI-DATA MSX
Unit Type
Standalone
Input Type
Voltage
Analog Inputs
4,
8,
16
Field Interface
Sync Pulse
Resolution
24-bit
  • 16/8 Differential Inputs
  • Strain Gauge Inputs
  • 24-bit Resolution
  • Optical Isolation 1000 V
  • Simultaneous Sampling of up to 8 Channels
  • 24 Digital Trigger Input
  • 64 MB Onboard SDRAM for Data Storage
  • Robust Metal Housing
Family
ADDI-DATA MSX
Unit Type
Standalone
Input Type
Strain Gauge
Analog Inputs
8,
16
Field Interface
Sync Pulse
Resolution
24-bit
  • 16 Analog Inputs, Differential
  • Voltage or Current Inputs
  • 16-bit Resolution
  • Acquisition, Visualization & Analysis on One Device
  • No Software Installation Needed
  • Automatic Storage of Measured Values
  • 4 GB Built-in Flash Memory
  • Robust Metal Housing
Family
ADDI-DATA MSX
Unit Type
Standalone
Input Type
Voltage,
Current
Analog Inputs
16
Resolution
16-bit
Communication
Ethernet
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us
© A-Tech Instruments Ltd.