2110, Thermocouple/RTD Digital Panel Meter
- Panel Mount Indicator
- Thermocouple or RTD Inputs
- Protection Class: IP65
- RS-232/485 Interface (Option)
- Isolated Relay Output (Option)
- Isolated Analog Output (Option)
- Low AC/DC Power Supply (Option)
- Overvoltage Protection
Input Type | Thermocouple/RTD |
No. of Inputs | 1 |
Output Type | DC Voltage |
DC Current | |
Relay | |
Interface | RS-232/485 |
Supply Power | 9 - 32 V DC |
8 - 28 V AC | |
85 - 250 V AC | |
IP Rating | IP65 |
2110-1 | Type J, -210°C to 760°C |
2110-2 | Type J, -347°F to 1400°F |
2111-1 | Type K, -244°C to 1372°C |
2111-2 | Type K, -408°F to 2501°F |
2112-1 | Type T, -257°C to 400°C |
2112-2 | Type T, -430°F to 752°F |
2113-1 | Type E, -240°C to 1000°C |
2113-2 | Type E, -400°F to 1830°F |
2114-1 | Type N, -244°C to 1372°C |
2114-2 | Type N, -408°F to 2501°F |
2115-1 | Type S, -46°C to 1768°C |
2115-2 | Type S, -51°F to 3213°F |
2116-1 | Type R, -45°C to 1768°C |
2116-2 | Type R, -49°C to 3214°F |
2118-1 | DIN Type RTD, -202°C to 850°C |
2118-2 | DIN Type RTD, -331°F to 1562°F |
2119-1 | ANSI Type RTD, -202°C to 850°C |
2119-2 | ANSI Type RTD, -331°F to 1562°F |
2110 Thermocouple Digital Panel Meter Datasheet |
2110 RTD Digital Panel Meter Datasheet |
- Digital Display Indicator
- Analog or Frequency Input
- Range of Mathematic Functions
- Protection Class: IP65
- RS-232/485 Interface (Option)
- Analog Outputs (Option)
- Relay Outputs (Option)
- Linearization of up to 16 Steps
Input Type | DC Voltage, DC Current |
No. of Inputs | 1 |
Excitation | 10 V DC, 12 V DC, 24 V DC |
Output Type | DC Voltage, DC Current, Relay |
Interface | RS-232/485 |
Supply Power | 11 - 36 V DC, 85 - 250 V AC |
- Panel Mount Indicator
- Quadrature Encoder Inputs
- Protection Class: IP65
- RS-232/485 Interface (Option)
- Isolated Relay Output (Option)
- Isolated Analog Output (Option)
- Low AC/DC Power Supply (Option)
- Overvoltage Protection
Input Type | Encoder |
No. of Inputs | 1 |
Excitation | 5 V DC, 10 V DC, 24 V DC |
Output Type | DC Voltage, DC Current, Relay |
Interface | RS-232/485 |
Supply Power | 9 - 32 V DC, 8 - 28 V AC, 85 - 250 V AC |
- Panel Mount Indicator
- DC Voltage Analog Inputs
- Protection Class: IP65
- RS-232/485 or BCD Interface (Option)
- Isolated Relay Output (Option)
- Isolated Analog Output (Option)
- Low AC/DC Power Supply (Option)
- Overvoltage Protection
Input Type | DC Voltage |
No. of Inputs | 1 |
Excitation | 5 V DC, 10 V DC, 24 V DC |
Output Type | DC Voltage, DC Current, Relay |
Interface | RS-232/485 |
Supply Power | 9 - 32 V DC, 8 - 28 V AC, 85 - 250 V AC |
- Panel Mount Indicator
- DC Current Analog Inputs
- Protection Class: IP65
- RS-232/485 or BCD Interface (Option)
- Isolated Relay Output (Option)
- Isolated Analog Output (Option)
- Low AC/DC Power Supply (Option)
- Overcurrent Protection
Input Type | DC Current |
No. of Inputs | 1 |
Excitation | 5 V DC, 10 V DC, 24 V DC |
Output Type | DC Voltage, DC Current, Relay |
Interface | RS-232/485 |
Supply Power | 9 - 32 V DC, 8 - 28 V AC, 85 - 250 V AC |
- Panel Mount Indicator
- Process Signal Inputs
- Protection Class: IP65
- Custom Scaling (Model 2162X)
- RS-232/485 Interface (Option)
- Isolated Relay Output (Option)
- Isolated Analog Output (Option)
- Low AC/DC Power Supply (Option)
Input Type | DC Current |
No. of Inputs | 1 |
Excitation | 5 V DC, 10 V DC, 24 V DC |
Output Type | DC Voltage, DC Current, Relay |
Interface | RS-232/485 |
Supply Power | 9 - 32 V DC, 8 - 28 V AC, 85 - 250 V AC |